Acta ophthalmologica

Comparative diagnostic performance of digital and conventional tests for congenital red-green colour vision deficiency.

Marina Vilella, Victor I Fernandez-Fernandez, Jesús Carballo-Álvarez, Amelia Nieto-Bona, Eduardo Esteban-Ibañez

Ophthalmology Department, Aragón Health Research Institute (IIS Aragon), Miguel Servet University Hospital, Zaragoza, Spain. · Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain.

Observational · n=30

Key points

From the paper's conclusion
  • Diagnostic performance varied across colour vision tests. DIVE Touch showed high specificity, moderate sensitivity and substantial agreement with CAD, whereas DIVE Eye-Tracking maintained high specificity but showed lower sensitivity and requires further optimisation.

Abstract

PURPOSE: To compare the diagnostic performance of the DIVE Colour Test for detecting congenital red-green (RG) colour vision deficiency, using the Colour Assessment and Diagnosis (CAD) test as the reference standard, with established conventional colour vision tests providing within-sample benchmarks. METHODS: Sixty participants were enrolled in an observational study: 30 CAD-confirmed normal trichromats and 30 participants with congenital RG deficiency. Each completed the CAD test, DIVE Colour Test (touch and eye-tracking), Nagel anomaloscope, Ishihara 38 Plates Test and Roth 28-Hue Test. Diagnostic accuracy against CAD was assessed using sensitivity, specificity and Cohen's kappa (k), both in right-eye and binocular testing. RESULTS: In right-eye testing, DIVE Touch achieved a sensitivity of 78.1% and a specificity of 100.0%, demonstrating substantial agreement with CAD (κ = 0.77). In comparison, DIVE eye-tracking showed lower sensitivity (53.1%) while maintaining high specificity (96.4%), yielding moderate agreement with CAD (κ = 0.48). Regarding the binocular analysis: DIVE Touch yielded a sensitivity of 69.0%, a specificity of 100.0% and substantial agreement with CAD (κ = 0.69). Among conventional tests versus CAD, Ishihara showed the highest sensitivity with complete specificity, the Nagel anomaloscope achieved substantial agreement, and the Roth 28-Hue Test showed the lowest sensitivity for RG classification. CONCLUSION: Diagnostic performance varied across colour vision tests. DIVE Touch showed high specificity, moderate sensitivity and substantial agreement with CAD, whereas DIVE Eye-Tracking maintained high specificity but showed lower sensitivity and requires further optimisation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers