Journal of medical imaging and radiation oncology

Ergonomic Setup for Trans-Radial Procedures Using a Height-Adjustable Trolley in the Angiography Suite.

Akshay Kohli, Terrence C Hui, Glen Schlaphoff

Department of Interventional Radiology, Liverpool Hospital, Sydney, New South Wales, Australia. · Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore, Singapore.

Key points

From the paper's conclusion
  • The implementation of a height-adjustable trolley provides a simple, cost-effective, and highly adaptable ergonomic solution that optimizes procedural efficiency, sterile field integrity, and radiation safety during trans-radial interventional procedures.

Abstract

BACKGROUND: Trans-radial access (TRA), while experiencing varying global adoption among interventional radiologists, offers potential benefits including reduced access-site bleeding, accelerated patient ambulation, and decreased overall healthcare expenditures compared with trans-femoral access (TFA). However, TRA introduces distinct occupational ergonomic burdens, including asymmetrical arm abduction, working height discrepancies with standard angiographic tables, and inadequate support for long microcatheters and guidewires. These biomechanical constraints heighten operator fatigue and increase the cumulative risk of work-related musculoskeletal disorders. TECHNIQUE: A mobile, height-adjustable trolley-conceptually adapted from ergonomic sit-stand workstations-was integrated into the angiography suite workflow. Arranged parallel to the patient in a Z-shaped spatial configuration, the trolley is linked to the patient's outstretched access arm using an extended sterile drape to establish a stable, continuous sterile working platform. CLINICAL IMPLICATIONS: This technical configuration restores neutral operator posture, mitigates lumbar torsion and cervical strain, eliminates sterile field breaches from suspended equipment, and increases the physical working distance from primary scatter radiation sources. Furthermore, the elevated surface facilitates gravity-assisted administration of dense Yttrium-90 microspheres during radioembolization and prevents rotational interference during cone-beam computed tomography acquisitions. CONCLUSION: The implementation of a height-adjustable trolley provides a simple, cost-effective, and highly adaptable ergonomic solution that optimizes procedural efficiency, sterile field integrity, and radiation safety during trans-radial interventional procedures.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers