Vascular and endovascular surgery

Snare Assisted Guiding Catheter Stabilization for Left Internal Carotid Artery Access via Right Distal Radial Approach.

Yuya Kobayashi, Yoshiki Hanaoka, Chinami Yuzawa, Minori Kurashina, Atsushi Sato, Yoshiki Sekijima

Department of Neurology, Ina Central Hospital, Ina, Japan. · Department of Neurosurgery, Ina Central Hospital, Ina, Japan.

Case report

Key points

From the paper's conclusion
  • We report a case in which a stable guiding system was established via a right distal radial approach by capturing the guiding catheter with a snare and applying traction.

Abstract

Transradial approach (TRA) is increasingly adopted in neurointervention. However, distal system advancement to the left internal carotid artery (ICA) via a right radial approach can be technically challenging, particularly when a small-caliber system is required. We report a case in which a stable guiding system was established via a right distal radial approach by capturing the guiding catheter with a snare and applying traction. Despite marked ICA tortuosity, distal advancement of the distal access catheter and system push during flow diverter deployment were successfully achieved. This single-case technical experience suggests that snare-assisted guiding catheter stabilization may represent one technical option for addressing support limitations in challenging TRA procedures.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers