Comparing clinical laboratory beta-hydroxybutyrate testing of vitreous humor against toxicological blood analyses in ketoacidosis deaths.
Quinn Basso, Jacqueline Parai, Betty L C Chow, Christopher Milroy
Department of Pathology and Laboratory Medicine, University of Ottawa, Ottawa, Ontario, Canada. · Centre of Forensic Sciences, Toronto, Ontario, Canada.
Key points
From the paper's conclusion- These findings support biochemical testing of vitreous humor as a reliable modality for BHB analysis and outline diagnostic thresholds for differentiating fatal DKA and AKA.
Abstract
Beta-hydroxybutyrate (BHB) is used in investigations to detect ketoacidotic states. Standard chromatographic methods of analysis of blood have traditionally been used to assess BHB levels. More recently, vitreous humor has been an alternative matrix/body fluid in clinical laboratory testing. A retrospective case-control study was conducted on 406 adult autopsies performed between 2016 and 2024 where toxicologic testing of blood BHB had been performed. Quantitated postmortem blood toxicology BHB concentrations and clinical laboratory values of vitreous humor were compared. Blood BHB concentration was measured either by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS), while vitreous BHB concentration was quantified enzymatically. Cases were classified as no ketoacidosis, diabetic ketoacidosis (DKA), alcoholic ketoacidosis (AKA), hypothermia, or ketoacidosis not otherwise specified (NOS) based on BHB levels, postmortem glycated hemoglobin (HbA1c) concentration, case history, and autopsy findings. Correlation and regression analyses compared blood to vitreous BHB, and receiver-operating characteristic (ROC) curves were used to establish separate thresholds for the diagnosis of DKA and AKA by vitreous biochemistry. Vitreous BHB correlated strongly with blood BHB across both toxicologic methods (Pearson r > 0.94). ROC curves identified vitreous BHB thresholds of 478 mg/L (4.60 mmol/L) for fatal DKA (n = 39; sensitivity 94.9%, specificity 100%) and 283 mg/L (2.72 mmol/L) for AKA (n = 33; sensitivity 97.0%, specificity 93.4%); both with areas under the curve exceeding 0.97. These findings support biochemical testing of vitreous humor as a reliable modality for BHB analysis and outline diagnostic thresholds for differentiating fatal DKA and AKA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-386 Evaluation of near patient beta hydroxybutyrate testing in post mortem samples using the StatStrip analyserClinical Chemistry · 2026
- A-360 Performance of rapid glucose and ketone screening methods in post-mortem vitreous fluid samples to determine ketoacidosis-mediated deathClinical Chemistry · 2026
- B-406 The reliability of a significantly raised acetone (>10mg/100mL blood) to diagnose ketoacidosis in post mortem caseworkClinical Chemistry · 2026
- A-159 Specificity of beta hydroxybutyrate in the confirmation of insulin-induced hypoglycemia in post mortem casesClinical Chemistry · 2026
- Alcohol-associated attenuation of postmortem β-hydroxybutyrate and complementary biochemical findings in fatal hypothermia.Forensic science international · 2026
- B-028 Review of a sample exchange program for postmortem vitreous biochemical analysisClinical Chemistry · 2026