Acoustic and Thermal Characterization of Tissue-Mimicking Phantoms for Modeling Focused Ultrasound Hyperthermia.
David Bustamante, Yan Yan, Yeidi Yuja Vaquiz, Kevin Parker, Dario B Rodrigues, Mohammad Mehrmohammadi
Key points
From the paper's conclusion- We developed a reproducible workflow to characterize phantom properties and evaluated the optimal phantom in heating experiments (5-min heating followed by 5-min cooling) using a 256-element ring array ultrasound transducer.
Abstract
Focused ultrasound hyperthermia (HT) uses focused acoustic energy to elevate tissue temperature for therapeutic purposes. Achieving precise thermal dosimetry requires accurate modeling of acoustic heating, which depends on reliable measurements of the material properties of the medium being heated. Tissue-mimicking phantoms (TMPs) are essential tools in therapeutic ultrasound to validate and optimize HT treatment strategies, but their acoustic and thermal properties often vary due to fabrication methods. In this study, TMPs were fabricated using polyvinyl chloride (PVC) plastisol with 0%, 1%, and 4% (w/v) graphite to increase acoustic attenuation. We developed a reproducible workflow to characterize phantom properties and evaluated the optimal phantom in heating experiments (5-min heating followed by 5-min cooling) using a 256-element ring array ultrasound transducer. We then conducted in silico tests replicating these experiments using k-Wave and COMSOL Multiphysics. Acoustic attenuation (1.09-1.48 dB/MHz/cm), sound speed (1407.9-1412.1 m/s), and density (996.7-1036.7 kg/m3) were measured at therapeutic frequencies (1.0-2.2 MHz). Thermal conductivity increased with graphite content (0.152-0.189 W/m/K), while specific heat capacity ranged from 1688.8 to 1771.6 J/kg/K. Using a phantom with 1% graphite, the ring array ultrasound transducer produced a 4.4 °C temperature rise after 5 min of heating at 1.5 MHz. Using the measured properties, both computational studies yielded close agreement with experimental heating and cooling curves within a maximum error of 0.3 °C. This workflow provides a practical, reproducible strategy for phantom characterization, thereby improving the accuracy of HT computational modeling, which serves as a basis for clinical ultrasound treatment planning systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and base validation of a small-animal hyperthermia applicator.Physics in medicine and biology · 2026
- Impact of acoustic property uncertainty on transcranial ultrasound simulationbioRxiv · 2026
- Experimental Validation of Skull Acoustic Modelling Strategies for Transcranial Focused Ultrasound Simulation: A Cross-Comparison Study.Physics in medicine and biology · 2026
- Multifactorial regulation of ultrasound-induced cavitation by engineered silica nanoparticlesUltrasonics Sonochemistry · 2026
- Fluid-layer-assisted mold temperature control for injection-molded bridge-type compliant mechanisms: Experimental thermal validation and simulation-based benchmarking against conventional cooling channels.PloS one · 2026
- Design and evaluation of a deformable multi-organ abdominal phantom for multimodality imaging applications.Proceedings of SPIE--the International Society for Optical Engineering · 2026