Dissipativity-Based Multiport Stability Root-Cause Identification and Mitigation for Solid-State Transformers
Xiangyu Meng, Dong Xie, Hongjian Lin, Chunxu Lin, Xinglai Ge, Zhigang Liu
Southwest Jiaotong University · Hunan University
Key points
From the paper's conclusion- Finally, the stability analysis and the effectiveness of the enhancement strategy are validated on a down-scaled SST prototype.
Abstract
For solid-state transformers (SSTs) in high-power grid-connected applications, improperly designed control loops can excite strong inherent AC-DC port coupling, leading to low-frequency oscillation issues, especially under weak grid conditions. To address this problem, this article establishes a multiport admittance matrix for the SST, encompassing its AC$\boldsymbol{dq}$axes and primary DC port, to characterize its inherent dynamics. Subsequently, a multiport dissipativity analysis is conducted to evaluate the robust stability of SST. By leveraging the decomposition of passivity conditions into distinct self- and coupling-dissipativity indices, the specific root causes of instability are diagnosed. This framework reveals that a severe coupling-dissipativity failure, induced by the internal dynamics of the synchronization loop, is the dominant instability mechanism rather than a localized self-dissipativity issue. Guided by this diagnosis, a stabilizing controller featuring dynamics-free orthogonal signal reconstruction is designed to reshape the admittance characteristics of the SST. This enhancement specifically targets the identified coupling-dissipativity deficiencies, thereby resolving the root cause of the instability. Finally, the stability analysis and the effectiveness of the enhancement strategy are validated on a down-scaled SST prototype. Experimental results demonstrate that the criterion accurately predicts the coupling-induced oscillations and that the enhanced controller guarantees stable operation under challenging weak-grid conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dynamic Stability Analysis and Experimental Validation of a High-Frequency Transformer Integrated Dual Active Bridge Converter for Solid-State Transformer ApplicationsEngineering Research Express · 2026
- Real-time EMT assessment of inverter supplementary control based on PCC power sensing for oscillation dampingat - Automatisierungstechnik · 2026
- Improved linear active disturbance rejection control for mitigating subsynchronous control interaction in DFIG systems.ISA transactions · 2026
- Two-stage stability enhancement framework based on S-domain modal analysis for renewable energy power systemsInternational Journal of Electrical Power & Energy Systems · 2026
- Eigenvalue-Sensitivity-Based Damping Signal Placement for Subsynchronous Resonance Mitigation in DFIG Wind FarmsElectronics · 2026
- Adaptive Damping Control for Stability Enhancement of Grid-Following Converters Based on q-Axis Voltage Magnitude FeedbackEnergies · 2026