Eigenvalue-Sensitivity-Based Damping Signal Placement for Subsynchronous Resonance Mitigation in DFIG Wind Farms
Jomana M. Helmi, Rizk M. Hamouda, Hadi M. Elhelw, Ahmed Abu-Siada
Key points
From the paper's conclusion- Subsynchronous resonance (SSR) in doubly fed induction generator (DFIG)-based wind farms connected to series capacitor-compensated networks can be strongly influenced by the location of supplementary damping control.
Abstract
Subsynchronous resonance (SSR) in doubly fed induction generator (DFIG)-based wind farms connected to series capacitor-compensated networks can be strongly influenced by the location of supplementary damping control. This paper proposes a mode-targeted eigenvalue sensitivity framework for identifying the most effective stabilizing signal injection location prior to controller tuning. In this regard, a unified dynamic model incorporating the drivetrain, DFIG, converter controls, DC link, and series compensated network is linearized for modal analysis. Participation factors identify the dominant states associated with the critical SSR mode and support the use of generator speed deviation as a suitable common feedback signal. The real part sensitivity of the critical eigenvalue to stabilizer gain is then evaluated for four candidate injection locations: the rotor-side converter (RSC) torque and reactive power control loops, and the grid-side converter (GSC) DC link and terminal voltage control loops. Among these locations, the RSC torque loop exhibits the strongest stabilizing sensitivity. Eigenvalue migration and time-domain simulations under identical operating and control conditions confirm the same ranking, while the SSR modal frequency remains essentially unchanged. The proposed approach provides a quantitative and physically interpretable means of determining the stabilizer location independently of controller tuning, offering a systematic strategy for SSR mitigation in converter-interfaced power systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improved linear active disturbance rejection control for mitigating subsynchronous control interaction in DFIG systems.ISA transactions · 2026
- Subsynchronous Oscillation Parameters Identification Method for DFIG Based on NGO‐Optimized MVMD and Improved TLS‐ESPRITInternational Transactions on Electrical Energy Systems · 2026
- Stability Assessment Method for DFIG-Based Wind Energy SystemsAlgorithms · 2026
- Small-Signal Stability Enhancement of Grid-Side Converters for Permanent-Magnet Wind Turbines via Adaptive Leaky Impedance-Reshaping CompensationProcesses · 2026
- Vector Synchronization Stabilizer to Enhance Small-Signal Stability of VSC-Dominant Power System in DC-Voltage Control TimescaleCSEE Journal of Power and Energy Systems · 2026
- A Hybrid Power Synchronization Scheme for Stability Enhancement of Virtual Synchronous Generator ControlIEEE Transactions on Power Electronics · 2025