Analysis of the Evolution of Accidental Transients in the Cooling of a MgB₂ -LH₂ Hybrid Power Cable
Laura Maria Borges Savoldi, M. Bracco, Marco Breschi, Lorenzo Cavallucci, S. Farinon, Niccolò Gallino, Antonio Macchiagodena, Giovanni Mangiulli,
Politecnico di Torino · University of Bologna
Key points
From the paper's conclusion- This study analyzes the evolution of accidental transients in the cooling of a submarine 30 km hybrid cable in MgB2, capable to transfer 10kA at 30 kV and a mass flow rate up to 1 kg/s of LH2at 20 K.
Abstract
The safe and reliable operation of superconducting cables is critically dependent on efficient cooling strategies, and this point becomes even more relevant when hybrid cables cooled by liquid hydrogen (LH2) considered. This study analyzes the evolution of accidental transients in the cooling of a submarine 30 km hybrid cable in MgB2, capable to transfer 10kA at 30 kV and a mass flow rate up to 1 kg/s of LH2at 20 K. Three key failure scenarios are examined: a loss-of-flow accident (LOFA), a loss-of coolant accident (LOCA) and a loss-of-vacuum accident (LOVA). For each of the accidents, the phenomenology leading to the cable cooling deterioration is first discussed and the qualitative or quantitative evolution of the thermal-hydraulic transient in an unprotected situation is presented. The diagnostics most suited to detect the accident are then identified. This work, the first of its kind, suggests instrumentation to detect the occurrence of the different scenarios to protect the investment associated with the future hybrid power cables. The analysis shows that the loss of flow is easy to detect and the operators can reduce the cable power without any loss of LH2. The LOCA is more severe, as it requires fast detection that could be achieved using optic fibers, whereas overpressures and opening of relief valves are difficult to avoid especially for large ruptures. The LOVA is the most severe among the accidents investigated here, as it is difficult to detect without optic fibers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of Electric Fault in a MV DC MgB₂ Transmission Line Cooled by Liquid HydrogenIEEE Transactions on Applied Superconductivity · 2026
- Physical aspects and modelling approach to a core disruptive accident in a heavy liquid metal fast reactorEPJ Nuclear Sciences & Technologies · 2026
- Scaling laws for contamination traversal times during vacuum breaks in superconducting acceleratorsarXiv · 2026
- Transient Analysis Framework for Heat Pipe Reactors Based on the MOOSE and Its Validation with the KRUSTY ReactorEnergies · 2026
- A Study on Grounding Fault Diagnosis for a 500 kV AC Submarine Cable Using a 1D-CNN–BiLSTM Hybrid Neural Network ModelEnergies · 2026
- Prediction of Cable Thermal Failure in Switchgear Rooms of Nuclear Power Plants Based on Numerical Simulation and Deep LearningFire · 2026