A Study on Grounding Fault Diagnosis for a 500 kV AC Submarine Cable Using a 1D-CNN–BiLSTM Hybrid Neural Network Model
Yu Ma, Jialin Zhang, Yong Yang, Xiangrong Chen, Zelin Hong, Yuchen Wang
Key points
From the paper's conclusion- This paper proposes a submarine cable fault diagnosis method based on the hybrid neural network of 1D-CNN-BiLSTM, which takes the one-dimensional time-domain relationship of sheath and armor grounding currents at the cable head and end as network input.
Abstract
Extra-high voltage submarine cables serve as a vital component for new energy grid integration and island power grids, and reliable diagnosis of their grounding faults is of great significance to the safe and stable operation of the power system. This paper proposes a submarine cable fault diagnosis method based on the hybrid neural network of 1D-CNN-BiLSTM, which takes the one-dimensional time-domain relationship of sheath and armor grounding currents at the cable head and end as network input. Firstly, the One-dimensional Convolutional Neural Network (1D-CNN) is adopted to automatically extract local high-dimensional time-series features and compress data length. Subsequently, the Bidirectional Long Short-Term Memory network (BiLSTM) models forward and backward information to capture feature variations during fault evolution, so as to improve the diagnosis accuracy of submarine cable grounding faults. The proposed model is applied to the grounding fault diagnosis of a 500 kV high-voltage AC submarine cable system connecting Zhenhai in Ningbo and Dapeng Island in Zhoushan. The results show that the proposed model achieves a mean classification accuracy of 97.35% and a macro-F1 score of 97.36% over 20 independent training runs, with an accuracy standard deviation of 0.592 percentage points, demonstrating high classification performance and training repeatability. The mean single-window inference time is approximately 1.451 ms. Furthermore, robustness evaluations under Gaussian white noise and harmonic interference show that the mean classification accuracy remains above 96.9% under all investigated disturbance conditions, indicating limited sensitivity to the considered signal perturbations. By automatically extracting discriminative features from grounding-current waveforms without manual feature engineering, the proposed method provides an effective approach for classifying typical grounding faults and offers a useful reference for online condition monitoring and fault diagnosis of extra-high-voltage AC submarine cable systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Research on cable condition evaluation method based on multi-sensor information fusionAIP Advances · 2026
- Hybrid CNN-decision tree framework for efficient transmission line fault detection and classification: an XAI-based approachScientific Reports · 2026
- Overview of Monitoring, Diagnostics, Aging Analysis, and Maintenance Strategies in High-Voltage AC/DC XLPE Cable SystemsSensors · 2025
- Artificial Intelligence-Based Optimization of Grounding Systems for 400 V, 10 kV, and 35 kV Electrical Installations: A Comparative Study.Journal of visualized experiments : JoVE · 2026
- Physics-grounded sequence-domain graph learning for adaptive fault location in IBR-dominated offshore wind farm transmission networksDiscover Artificial Intelligence · 2026
- Research on Fault Diagnosis and Classification of High‐Voltage Transmission Lines Based on an Improved CNN ModelInternational Transactions on Electrical Energy Systems · 2026