IEEE journal of translational engineering in health and medicine

CALM: Cycle-Aware Latent Modeling for Arteriovenous Fistula Assessment Using Audio Foundation Models and Low-Level Descriptors.

Whenty Ariyanti, Ping-Yi Lin, Chia-Yu Hu, Shang-Feng Yang, Shin-Hung Tsai, Li-Ning Peng, Po-Hsun Huang, Hsin-Min Wang,

Department of Computer Science and Information EngineeringNational Taiwan University of Science and Technology Taipei 106335 Taiwan. · Department of SurgeryMinistry of Health and Welfare, Taoyuan Hospital Taoyuan 330215 Taiwan.

Key points

From the paper's conclusion
  • The proposed framework demonstrates the feasibility of AFM-based auscultation for non-invasive AVF flow assessment. By combining physiologic signal modeling with foundation model representations, CALM provides a robust and objective framework for automated assessment of vascular access function.

Abstract

OBJECTIVE: Arteriovenous fistula (AVF) dysfunction is a major cause of morbidity in hemodialysis (HD) patients. Although conventional monitoring tools are clinically effective, they are often limited by cost, invasiveness, and operator dependence. This study proposes a cycle-aware, auscultation-based deep learning framework for objective and scalable assessment of AVF blood flow status. METHODS AND PROCEDURES: We developed CALM, a physiologically informed learning framework that integrates Hilbert-based cycle segmentation with pretrained audio foundation model (AFM) representations. A clinical auscultation dataset (CHGH-AVF) from 188 HD patients at three standardized vascular access sites was collected and labeled using concurrent blood flow measurements. The proposed approach was evaluated on both three-class flow-severity classification (Low, Medium, and High) and binary flow-quality screening (Ideal vs. Unideal). Model variants incorporating domain-specific low-level descriptors and different feature fusion strategies were also investigated. RESULTS: Across all auscultation sites, CALM consistently outperformed conventional handcrafted-feature baselines, deep learning baselines, and classical machine learning-based classifiers in patient-level flow-severity classification. Ablation studies demonstrated that physiologic cycle segmentation substantially improves discriminability, while integrating complementary low-level descriptors (LLDs) further enhanced performance across anatomically different recording locations. Although classification performance remained highest at the proximal sites, reduced performance at the venous site highlighted the influence of anatomical location and signal quality. Strong performance was also observed for binary flow-quality monitoring, particularly at the proximal auscultation sites. CONCLUSION: The proposed framework demonstrates the feasibility of AFM-based auscultation for non-invasive AVF flow assessment. By combining physiologic signal modeling with foundation model representations, CALM provides a robust and objective framework for automated assessment of vascular access function. CLINICAL IMPACT: This work introduces a multi-site clinical AVF auscultation dataset and establishes automated auscultation analysis as a low-cost and scalable adjunct to existing vascular access monitoring practices in HD care.Clinical and Translational Impact Statement: AFM-based auscultation has the potential to support objective screening of AVF dysfunction and may facilitate future integration into bedside or home monitoring systems, enabling more accessible and scalable vascular access monitoring.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

CALM: Cycle-Aware Latent Modeling for Arteriovenous Fistula Assessment Using Audio Foundation Models and Low-Level Descriptors — Science Skim