CardioSynx: A Pilot Study of a Low-Latency AI-Assisted Phonocardiography System with concurrent Processing for Real-Time Valvular Heart Disease Diagnosis.
Mariam Mansoor, Asim Waris, Muhammad Jawad Khan, Mohsin Jamil, Muhammad Shaheryar Nazir, Dingchang Zheng, Fawwaz Hazzazi, Muhammad Adeel Ijaz,
Key points
From the paper's conclusion- The model was deployed for real-time, continuous, low-latency operation using concurrent processing that handled audio capture, denoising, feature extraction, and classification.
Abstract
Timely Diagnosis of Cardiovascular diseases is crucial, as delayed detection of valve disease increases mortality risk. Stethoscopes are widely used by clinicians for cardiac assessment but remains subjective and misses early pathological changes. Phonocardiography provides a non-invasive tool for objective assessment, while recent advances in digital stethoscopes have enabled automated Phonocardiography analysis. Most prior studies have shown high offline accuracies but lacked real-time applicability because of high computational cost. Existing real-time systems face challenges of high latency, noise, binary classification, and remain clinically untested. This study introduces CardioSynx, a real-time PCG classification system integrating a digital stethoscope, lightweight one-dimensional convolutional-neural-network, and graphical user interface. The model was trained offline on a balanced five-class PCG dataset, pre-processed using Butterworth filtering, Hilbert envelope isolation, and Wavelet denoising, achieving an accuracy 97.5%**0.22 on 5 classes. The model was deployed for real-time, continuous, low-latency operation using concurrent processing that handled audio capture, denoising, feature extraction, and classification. The system was tested on cardiac patients in a hospital. To the best of our knowledge this is the first pilot feasibility demonstration of a real-time multi-class PCG system in a clinical environment. Real-time testing across a cohort of 22 sessions achieved an accuracy of 90.9% (95% CI: 72.2%-97.5%). A mean frame-level latency of 60 ms was recorded, with an average segmental Signal-to-noise Ratio of 16.8 dB. The system generates diagnostic reports and audio files reviewable by clinicians. This preliminary evaluation serves as proof-of-concept, demonstrating a promising pathway for rapid AI-assisted cardiac screening in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Scaling to Multimodal and Multichannel Heart Sound Classification with Synthetic and Augmented Biosignals.Sensors (Basel, Switzerland) · 2026
- Real-time AI-based signal quality control enhances signal reliability and diagnostic stability in multi-site digital auscultationEuropean Heart Journal · 2026
- Clinically aligned hierarchical machine learning for patient-level classification of valvular regurgitation severity and subtype from phonocardiograms (PCG)European Heart Journal · 2026
- An Intra- and Inter-Individually Insensitive PCG Monitoring SoC for Long-Term Wearable Devices.IEEE transactions on biomedical circuits and systems · 2026
- Cross-Dataset Generalization in Phonocardiogram Murmur Classification: A Benchmark Study of Domain-Conditional Performance and the Role of Multi-Representation Fusion.Journal of clinical medicine · 2026
- TriFusion-PCGNet: A Hybrid Multi-Branch Deep Learning Network for Energy-Aware Normal/Abnormal Heart Sound Classification.Life (Basel, Switzerland) · 2026