IEEE journal of biomedical and health informatics

CardioSynx: A Pilot Study of a Low-Latency AI-Assisted Phonocardiography System with concurrent Processing for Real-Time Valvular Heart Disease Diagnosis.

Mariam Mansoor, Asim Waris, Muhammad Jawad Khan, Mohsin Jamil, Muhammad Shaheryar Nazir, Dingchang Zheng, Fawwaz Hazzazi, Muhammad Adeel Ijaz,

Key points

From the paper's conclusion
  • The model was deployed for real-time, continuous, low-latency operation using concurrent processing that handled audio capture, denoising, feature extraction, and classification.

Abstract

Timely Diagnosis of Cardiovascular diseases is crucial, as delayed detection of valve disease increases mortality risk. Stethoscopes are widely used by clinicians for cardiac assessment but remains subjective and misses early pathological changes. Phonocardiography provides a non-invasive tool for objective assessment, while recent advances in digital stethoscopes have enabled automated Phonocardiography analysis. Most prior studies have shown high offline accuracies but lacked real-time applicability because of high computational cost. Existing real-time systems face challenges of high latency, noise, binary classification, and remain clinically untested. This study introduces CardioSynx, a real-time PCG classification system integrating a digital stethoscope, lightweight one-dimensional convolutional-neural-network, and graphical user interface. The model was trained offline on a balanced five-class PCG dataset, pre-processed using Butterworth filtering, Hilbert envelope isolation, and Wavelet denoising, achieving an accuracy 97.5%**0.22 on 5 classes. The model was deployed for real-time, continuous, low-latency operation using concurrent processing that handled audio capture, denoising, feature extraction, and classification. The system was tested on cardiac patients in a hospital. To the best of our knowledge this is the first pilot feasibility demonstration of a real-time multi-class PCG system in a clinical environment. Real-time testing across a cohort of 22 sessions achieved an accuracy of 90.9% (95% CI: 72.2%-97.5%). A mean frame-level latency of 60 ms was recorded, with an average segmental Signal-to-noise Ratio of 16.8 dB. The system generates diagnostic reports and audio files reviewable by clinicians. This preliminary evaluation serves as proof-of-concept, demonstrating a promising pathway for rapid AI-assisted cardiac screening in clinical practice.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

CardioSynx: A Pilot Study of a Low-Latency AI-Assisted Phonocardiography System with concurrent Processing for Real-Time Valvular Heart Disease Diagnosis — Science Skim