Artificial Intelligence-Based Neonatal Seizure Detection: A Pragmatic Evaluation of Clinical Performance Tradeoffs in Clinical EEG.
Jennifer C Keene, Nicholas S Abend, Giulia M Benedetti, Zach Fulmer, Maire Keene, Saeed Montazeri, Craig Press, Nathan J Stevenson,
Department of Pediatrics, Division of Child Neurology, University of Utah, Salt Lake City, Utah, U.S.A. · Departments of Neurology and Pediatrics, Children's Hospital of Philadelphia and University of Pennsylvania, Philadelphia, Pennsylvania, U.S.A.
Key points
From the paper's conclusion- AI-based NSDs demonstrated high infant-level sensitivity but different tradeoffs between seizure-level detection and alarm burden. These findings highlight how AI tools may augment clinical EEG workflows and support earlier seizure recognition, while underscoring the need for evaluation under real-world conditions to guide safe and effective implementation.
Abstract
PURPOSE: The aim of this study was to evaluate how three artificial intelligence (AI)-based neonatal seizure detectors (NSDs) perform in a large, clinically acquired data set and their potential to support timely seizure identification. METHODS: We conducted a secondary analysis of continuous EEG (cEEG) recordings from 169 neonates born at ≥35 weeks gestation with neonatal encephalopathy. Seizure presence was determined by independent review by two or three pediatric encephalographers, and 2,455 individual seizures were annotated by a single expert as a pragmatic, clinically representative reference standard. Three NSDs were evaluated: a feature-based support vector machine detector (NSD1) and two deep-learning detectors (NSD2 and Persyst-15). Using an any-overlap approach, outcomes included neonate-level seizure identification, seizure-level detection, false detections per day (FD/day), and detection latency. RESULTS: We analyzed 15,343 hours of cEEG (median 98 hours per neonate); 55 neonates (33%) had seizures. All NSDs identified ≥95% of neonates with seizures. Seizure-level detection varied: NSD2 detected 35% (IQR 17-53%), NSD1 63% (IQR 38-82%), and Persyst-15 60% (IQR 37-80%) of seizures. NSD1 generated significantly more FDs (46 FD/day, IQR 22-82) than NSD2 (3.2 IQR 1.2-9.3) and Persyst-15 (2.8 IQR 1.1-6.2; P < 0.0001). The median time to first true detection was <1 minute for NSD1 and Persyst-15, versus 26 minutes for NSD2. CONCLUSIONS: AI-based NSDs demonstrated high infant-level sensitivity but different tradeoffs between seizure-level detection and alarm burden. These findings highlight how AI tools may augment clinical EEG workflows and support earlier seizure recognition, while underscoring the need for evaluation under real-world conditions to guide safe and effective implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Honest and Reliable Evaluation and Expert Equivalence Testing of Automated Neonatal Seizure Detection.Medical engineering & physics · 2026
- Deep learning architectures for EEG-based classification of Dravet syndrome: A comparative study of pre-trained and non-pretrained hybrid CNN-LSTM modelsPLoS ONE · 2026
- Automated EEG seizure detection in neonates with hypoxic–ischemic encephalopathy using temporal and morphological modelingFrontiers in Pediatrics · 2026
- Expert-level detection of low-voltage intervals in EEG as a robust biomarker of neonatal encephalopathyarXiv · 2026
- Comparison of a novel portable wireless multichannel EEG with inbuilt seizure detection algorithm to a conventional EEG in a term neonatal cohortFrontiers in Pediatrics · 2026
- Neonatal seizure detection from EEG using inception ResNetV2 feature extraction and XGBoost optimized with particle swarm optimizationScientific Reports · 2025