Expert-level detection of low-voltage intervals in EEG as a robust biomarker of neonatal encephalopathy
John M. O'Toole, Sean R. Mathieson, Aurel Luca, Soraia Ventura, Sean Griffin, Geraldine B. Boylan, Robert Hogan
Key points
From the paper's conclusion- We then tested the clinical relevance of detected LVIs across four applications: 1) grading background EEG abnormalities on an open benchmark dataset, 2) classifying clinical hypoxic-ischaemic encephalopathy (HIE) grades and comparing with a normal EEG dataset, 3) seizure prediction, and 4) association with seizure burden.
Abstract
Background: Discontinuity in neonatal EEG is a critical marker of brain dysfunction but can be difficult to quantify visually. Inter-burst intervals (IBIs) are a key characteristic of discontinuity, yet their definition does not easily translate to AI detection. Objectives: To introduce low-voltage intervals (LVIs), defined exclusively by amplitude and duration, as a context-independent alternative to IBIs, develop an AI detection method for LVIs, and assess their clinical utility as a marker of brain injury. Methods: We developed a ConvNeXt model to detect LVIs and compared its performance with existing methods. We then tested the clinical relevance of detected LVIs across four applications: 1) grading background EEG abnormalities on an open benchmark dataset, 2) classifying clinical hypoxic-ischaemic encephalopathy (HIE) grades and comparing with a normal EEG dataset, 3) seizure prediction, and 4) association with seizure burden. Results: For training and validation, 654 hours of per-channel EEG from 123 neonates were reviewed and 51,162 LVIs were annotated. On held-out validation, ConvNeXt had an AUC of 0.996 and a Matthews correlation coefficient of 0.926. Model-reader agreement exceeded inter-reader agreement ($\Delta \kappa = 0.025$, 95% CI: 0.007 to 0.045, $p<0.001$), attaining expert-level equivalence. On a combined dataset of 444 neonates, percentage LVI showed a strong association with EEG grades (Spearman's $\rho=0.801$), a moderate association with HIE grades ($\rho=0.384$), a weaker association with seizure burden ($\rho=0.244$), and a strong seizure prediction capacity (AUC $=0.872$). Conclusion: AI detection of LVIs achieves expert-level equivalence, whereas quantitative features do not. Automated LVI quantification provides a robust clinical biomarker of neonatal encephalopathy associated with background EEG activity, HIE severity, and seizure risk.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- U-NeXt: General-purpose event detection for neonatal EEGarXiv · 2026
- Automated EEG seizure detection in neonates with hypoxic–ischemic encephalopathy using temporal and morphological modelingFrontiers in Pediatrics · 2026
- GROND: Automated characterization of periodic and rhythmic EEG patterns.Journal of neural engineering · 2026
- Robust Epilepsy Diagnosis in Neonates Via Spatio-Temporal Graph Learning and Balanced Test-Time Training.IEEE transactions on bio-medical engineering · 2026
- Automated extraction of seizures and ictal-interictal continuum patterns from EEG reports to enable large-scale neurophysiology and neurocritical care research.International journal of medical informatics · 2026
- Video-Based Automated Seizure Classification Using Multimodal Large Language Models.Annals of clinical and translational neurology · 2026