Interpretability of the Quantra viscoelastic test in patients with haematological malignancies presenting severe thrombocytopenia.
Adrien Contejean, Florence Blanc-Jouvan, Noémie Zucman, Claire Reynes, Yacine Haddad, Cloe Derray, Constance Moulinier, Natacha Mauz,
Service d'hématologie. · Laboratoire d'hématologie.
Key points
From the paper's conclusion- Quantra results were interpretable in patients with haematological malignancies and platelet counts below 50 × 109/l and correlated both with ROTEM parameters and with conventional haemostasis assays.
Abstract
Viscoelastic tests have been scarcely evaluated in patients with haematological malignancies and severe thrombocytopenia. The VISCOTHEM-1 study investigated the interpretability of Quantra results in these patients, with platelet count less than 50 × 109/l. The objective was to evaluate the correlation between clot stiffness and platelet contribution to clot stiffness (PCS) measured by Quantra and conventional laboratory platelet counts. In this exploratory, single-centre, nonrandomized prospective cohort (June-December 2024), adults with haematological malignancies, platelet count less than 50 × 109/l and no antiplatelet/anticoagulant therapy or platelet-function disorders were enrolled. Patients underwent a blood count, coagulation assays, Quantra and ROTEM assessments. For patients who received transfusion, a second draw was performed one hour posttransfusion. Forty-six patients were included: 16 with platelet counts less than 10 × 109/l, 15 between 10 and 19 × 109/l, and 15 between 20 and 49 × 109/l. Fourteen patients (31%) experienced bleeding. The median PCS measured by Quantra was 2 hPa [interquartile range (IQR) 2-3.38] and correlated strongly with platelet count using conventional assay (r = 0.84, P < 0.05) and with MCE platelets measured by ROTEM (r = 0.78, P < 0.05). Clot stiffness was moderately correlated with platelet count (r = 0.48, P < 0.05) and strongly with MCF-EXTEM (r = 0.79, P < 0.05). The range of PCS values differentiated most patients except in the less than 10 × 109/l subgroup. The distributions of clot stiffness, clotting time and fibrinogen contribution to clot stiffness measured by Quantra reliably discriminated between all patients regardless of platelet count. After transfusion, PCS and clot stiffness increased significantly. Quantra results were interpretable in patients with haematological malignancies and platelet counts below 50 × 109/l and correlated both with ROTEM parameters and with conventional haemostasis assays.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 75. Quantra QStat Reference Range Verification in Third-Trimester Obstetric PatientsAmerican Journal of Clinical Pathology · 2026
- Assessment of cardiopulmonary bypass-induced platelet disorders using the Quantra Qplus system: the prospective single centre PLAQUA study.British journal of anaesthesia · 2026
- A-246 Population-Specific reference intervals: Establishment of pregnancy reference values for Quantra System's VET parametersClinical Chemistry · 2026
- Viscoelastic Testing for Assessment of Hypercoagulability and Thrombotic Risk in Cancer Patients: A Systematic Review.Cancers · 2026
- When the Donor Is the Root Cause: Platelet Concentrate Quality Control Failure Due to Constitutional Macroplatelets Detected During a Vertical Audit.Cureus · 2026
- A-249 Evaluation of three cartridge-based analyzers for viscoelastic testingClinical Chemistry · 2026