75. Quantra QStat Reference Range Verification in Third-Trimester Obstetric Patients
Homayemem Weli, Jenna Khan, Raeshun T Glover, Nicholas E Larkey
Key points
From the paper's conclusion- Among healthy third-trimester obstetric patients, the observed reference ranges were as follows: CT 95–137 s; CSL 93–100%; CS 19.3–43.9 hPa; PCS 14.7–36.1 hPa; and FCS 2.3–7.5 hPa.
Abstract
The Quantra system with QStat cartridge is used to assess coagulopathic states and was initially approved by the U.S. Food and Drug Administration (FDA) for trauma and liver transplantation, but not for obstetric use at the time of this study. Given its comparable analytical performance, faster turnaround time relative to other viscoelastic assays, and the clear clinical need in obstetrics, we sought to establish an institution-specific reference range to support its use in obstetric patients prior to FDA approval for this indication. Samples were randomly obtained from 71 verbally consented obstetric patients upon admission between November 2023 and March 2025. Inclusion criteria were non-bleeding patients in the third trimester of pregnancy. Patients receiving anticoagulant therapy or with incomplete data were excluded. Clot time (CT, seconds), clot stability to lysis (CSL, %), clot stiffness (CS, hPa), platelet contribution to clot stiffness (PCS, hPa), and fibrinogen contribution to clot stiffness (FCS, hPa) were measured. Reference ranges were established using the central 95% interval (2.5th–97.5th percentiles) and subsequently compared with recently FDA-approved reference ranges. Among healthy third-trimester obstetric patients, the observed reference ranges were as follows: CT 95–137 s; CSL 93–100%; CS 19.3–43.9 hPa; PCS 14.7–36.1 hPa; and FCS 2.3–7.5 hPa. Compared with standard adult reference ranges, CS, PCS, and FCS were shifted to higher values, likely reflecting the baseline higher levels of fibrinogen in this patient population. The laboratory-verified reference ranges demonstrated ≥95% concordance with the FDA-approved reference ranges, supporting their adoption without modification. Strong concordance was observed between our institutionally verified reference ranges and the FDA-approved ranges for the Quantra QStat cartridge. The observed differences between reference ranges in healthy obstetric patients and the general adult population underscore the physiologic alterations of pregnancy and highlight the importance of population-specific reference ranges to ensure accurate assessment of specialized physiologic states.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-246 Population-Specific reference intervals: Establishment of pregnancy reference values for Quantra System's VET parametersClinical Chemistry · 2026
- Interpretability of the Quantra viscoelastic test in patients with haematological malignancies presenting severe thrombocytopenia.Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis · 2026
- Development and Temporal Validation of a Thromboelastography-Based Nomogram for Queensland-Defined High Thrombotic Risk in Postpartum Women.Journal of visualized experiments : JoVE · 2026
- A-249 Evaluation of three cartridge-based analyzers for viscoelastic testingClinical Chemistry · 2026
- Quantra and ROTEM in Decompensated Cirrhosis: Method Comparison and Prognostic Value of Clot Time Ratio.International journal of laboratory hematology · 2026
- An Adaptable Quality Control Framework for Platelet-Rich Plasma as a Blood-Derived Product: A Multicenter Real-World Study.Pharmaceuticals (Basel, Switzerland) · 2026