Clinical Chemistry

A-246 Population-Specific reference intervals: Establishment of pregnancy reference values for Quantra System's VET parameters

Julie Navarro, Debbie Winegar, Robert Wiard, Robin Williamson

Observational · n=129

Key points

From the paper's conclusion
  • We aimed to establish the reference intervals for VET parameters: clot time (CT), clot stiffness (CS), platelet contribution to stiffness (PCS), and fibrinogen contribution to stiffness (FCS) using the QStat Cartridge in pregnant women in their third trimester experiencing a normal pregnancy based on CLSI EP28-A3c.

Abstract

Background Physiological changes during pregnancy include a progressive shift of hemostasis toward a hypercoagulable state that is protective against postpartum hemorrhage (PPH). However, those patients who experience PPH are at risk of developing an acquired, acute coagulopathy that requires rapid assessment to optimize pregnancy outcomes. Viscoelastic testing (VET) has been shown to provide rapid coagulation assessments at the point of care. Establishing validated, population-and assay-specific reference intervals enables timely recognition of coagulopathies to inform decision making. The Quantra® System is a cartridge-based VET system that uses ultrasound to measure the viscoelastic properties of whole blood. The QStat Cartridge is FDA-cleared for use at the point-of-care during liver transplantation, trauma, and peripartum obstetric procedures. We aimed to establish the reference intervals for VET parameters: clot time (CT), clot stiffness (CS), platelet contribution to stiffness (PCS), and fibrinogen contribution to stiffness (FCS) using the QStat Cartridge in pregnant women in their third trimester experiencing a normal pregnancy based on CLSI EP28-A3c. Methods This was a multicenter, prospective observational study. Pregnant women 18 years or older with a =28 weeks estimated gestational age singleton fetus without complications were included. Three blood samples were collected simultaneously from each participant, two 2.7 mL citrated blood collection tubes and one 3.0 mL EDTA tube. One of the citrated blood tubes was analyzed with the QStat Cartridge while the other two tubes were analyzed for standard coagulation parameters (aPTT, PT/INR, Clauss fibrinogen assay) and platelet count. Point estimates for reference intervals for each parameter were calculated using non-parametric methods and 95% confidence intervals were generated via a non-parametric approach Results Samples from 129 eligible participants were analyzed. The mean age of participants was 30.4 years, and the mean gestational age was 33.8 weeks. Table 1 provides the reference range intervals determined for the QStat parameters in pregnant women compared to the reference range intervals determined in a standard population consisting of healthy adult males and non-pregnant females. The obstetric reference intervals reflect the hypercoagulable state of late-stage pregnancy, characterized by shorter clot times and higher clot stiffness, particularly higher fibrinogen contribution to clot stiffness (FCS) compared to healthy non-pregnant individuals. Conclusion We established reference intervals for the Quantra System with the QStat Cartridge in third-trimester pregnant women. These population and assay-specific intervals enable accurate point-of-care interpretation of VET parameters, facilitating early identification of coagulation derangements to inform targeted therapies for the pregnant patient.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers