Uncorrected Visual Acuity and Visual Function Difficulties After Implantation of Simultaneous Vision Intraocular Lenses.
Joaquín Fernández, Filomena Ribeiro, H Burkhard Dick, Noemí Burguera, Manuel Rodríguez-Vallejo
Qvision, Department of Ophthalmology of VITHAS Almería Hospital, 04120, Almería, Spain. · Hospital da Luz, 1500-650 Lisbon, Portugal.
Key points
From the paper's conclusion- Only some VF-14 items were associated with binocular UVA. These findings may inform the development of PRO instruments for evaluating functional differences among SVIOLs.
Abstract
PURPOSE: To evaluate the association between binocular uncorrected visual acuity (UVA) at different distances and patient-reported difficulty with individual VF-14 activities after implantation of simultaneous vision intraocular lenses (SVIOLs). SETTING: ("Masked by journal requirement"). DESIGN: Retrospective observational. METHODS: Twelve-month data from 276 subjects implanted with either a Full-DOFi Smooth or a Partial-DOFi Extended IOL were included in the analysis. Visual acuities were obtained for far (UDVA, 4 m), intermediate (UIVA, 66 cm), and near (UNVA, 40 cm) distances, along with responses to a validated Spanish version of the VF-14 administered without spectacles. VF-14 responses were dichotomized (little/no vs other), and logistic regression analyses were performed to examine their associations with UDVA, UIVA, and UNVA. Statistical cut-off values were explored using the Youden index. RESULTS: UDVA was significantly associated with "traffic signs" and "night driving" (p < 0.05), whereas "watching TV" showed p = 0.06. UNVA was significantly associated with "knitting" (p < 0.05), whereas "large print" showed p = 0.06, and UIVA was associated with "newspapers" (p = 0.02). "Small print" and "knitting" were associated with both UIVA and UNVA, whereas "filling out forms" was associated only with UNVA (p < 0.05). Visual acuities were not associated with the remaining VF-14 items. Exploratory cut-off values maximizing the Youden index were generally 0.1 logMAR, except for "large print" (0.3 logMAR) and "traffic signs" (0.2 logMAR). CONCLUSIONS: Only some VF-14 items were associated with binocular UVA. These findings may inform the development of PRO instruments for evaluating functional differences among SVIOLs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Functional Visual Outcomes After Implantation of Refractive Segmental Multifocal Rotational Asymmetric Intraocular Lens.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Effect of Residual Astigmatism on Visual Acuity Following Bifocal, Trifocal, and Extended Depth-of-Focus Intraocular Lens Implantation: A Retrospective Cohort Study.Ophthalmology and therapy · 2026
- Impact of pupil size on defocus curve, contrast sensitivity and patient satisfaction in a diffractive, simultaneous vision intraocular lensJournal of Cataract & Refractive Surgery · 2026
- Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses.Journal of clinical medicine · 2026
- Visual Outcomes, Quality of Vision, and Quality of Life After Bilateral Implantation of a Trifocal Intraocular Lens With Mini-monovision.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Quantitative framework for synthesising defocus-curve evidence in simultaneous-vision intraocular lenses.The British journal of ophthalmology · 2026