Comparison of the Moussa Intraocular Lens Formula to contemporary formulas in a multicenter study.
Peter Kiraly, Hisham Hamze, Soon Ch'ng, George Moussa
Manchester Royal Eye Hospital, Manchester, Oxford Road, M13 9WL, U.K. · Birmingham Midlands Eye Centre, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK.
Key points
From the paper's conclusion- The Moussa formula demonstrated high predictive accuracy across multiple biometry platforms, with statistically lower overall MAE than the comparator formulas. Absolute differences from the closest-performing formulas were modest, and ±0.50D outcomes were similar to Kane and EVO. These findings support Moussa as a clinically relevant contemporary option for IOL power calculation, with encouraging results in short and long eyes requiring further targeted validation.
Abstract
PURPOSE: To evaluate the refractive predictive accuracy of the Moussa intraocular lens (IOL) formula compared with Kane, EVO, PEARL-DGS, K6, Hoffer-QST, and Barrett Universal II (BUII). SETTING: Birmingham Midland Eye Centre (Birmingham), Manchester Royal Eye Hospital and Newmedica (Manchester), UK. DESIGN: Multicenter, retrospective, consecutive, nonrandomized observational case series (September 2022-June 2025). METHODS: Included were one eye per patient undergoing uncomplicated phacoemulsification. Preoperative biometry used the IOLMaster 700, Lenstar LS900, or Pentacam AXL Wave. Lens-constants were optimized to zero mean prediction error (PE) for each formula and lens-biometer combination. Primary outcome was mean absolute error (MAE), evaluated using heteroscedastic studentized bootstrap analysis (2000 iterations; Holm correction). Secondary outcomes included median absolute error, root-mean-square error, standard deviation of PE, and proportions of eyes within ±0.25diopter (D) and ±0.50D. RESULTS: Included were 2550 patients (2550 eyes; mean age 74.0±10.0 years; 1068 male patients [41.9%]). Moussa produced a lower MAE (0.348 D) than Kane (0.359D), EVO (0.363D), PEARL-DGS (0.367D), K6 (0.367D), Hoffer-QST (0.377D), and BUII (0.379D; all p<.001). In short eyes (≤22.0mm), Moussa (0.412D) demonstrated lower error than K6 (p<.001), BUII (p<.001), Hoffer-QST (p=.008), EVO (p=.008), PEARL-DGS (p=.014), and Kane (p=.039). In long eyes (≥26.0 mm), Moussa (0.342 D) had lower error than Kane, BUII, Hoffer-QST (all p<.001), and K6 (p=.045), but not EVO (p=.068) or PEARL-DGS (p=.202). CONCLUSIONS: The Moussa formula demonstrated high predictive accuracy across multiple biometry platforms, with statistically lower overall MAE than the comparator formulas. Absolute differences from the closest-performing formulas were modest, and ±0.50D outcomes were similar to Kane and EVO. These findings support Moussa as a clinically relevant contemporary option for IOL power calculation, with encouraging results in short and long eyes requiring further targeted validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of the Accuracy of the Web-Based ESCRS IOL Power Calculator Formulas.Seminars in ophthalmology · 2026
- A retrospective multi-center validation study of tomography-based formulas for phakic intraocular lens sizing.Journal of cataract and refractive surgery · 2026
- Accuracy of Intraocular Lens Power Calculation Formulas for Two Single-Piece Acrylic IOL Models in Eyes with a Shallow Anterior Chamber.Bioengineering (Basel, Switzerland) · 2026
- Biometry-Guided IOL Formula Selection in Post-Laser Vision Correction Eyes.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- No-History IOL Power Calculation After Myopic Laser Vision Correction: A Multicenter Retrospective Database Study of 14 Formulas With and Without Posterior Corneal Curvature.American journal of ophthalmology · 2026
- Accuracy of 8 Intraocular Lens Power Calculation Formulas in Eyes Undergoing Combined Phacovitrectomy.Journal of ophthalmology · 2026