Accuracy of 8 Intraocular Lens Power Calculation Formulas in Eyes Undergoing Combined Phacovitrectomy.
Shiming Cheng, Xi Li, Qiong Yan, Jianqi Mei, Jiasheng Zhang, Guilian Shi, Junhai Lin, Tiantian Li,
Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China, wmu.edu.cn.
Key points
From the paper's conclusion- The 4 new-generation formulas showed higher accuracy overall, and higher accuracy was achieved using EVO and BUII formulas in long eyes. All formulas revealed satisfactory accuracy in short eyes. All formulas displayed better accuracy in medium eyes except for Hoffer Q.
Abstract
PURPOSE: To evaluate prediction accuracy using the 4 new-generation formulas (Barrett Universal II (BUII), Emmetropia Verifying Optical 2.0 (EVO), Kane, and Ladas Super Formula (LSF)) and 4 traditional formulas (Haigis, Hoffer Q, Holladay 1, and SRK/T) in eyes undergoing combined phacovitrectomy. METHODS: This is a retrospective case series study. In total, 249 eyes of 249 patients undergoing combined phacovitrectomy were enrolled. A single-piece foldable monofocal IOL was implanted in each case. The patients were categorized into three subgroups according to axial length (AL) results. RESULTS: Overall, the 4 new-generation formulas obtained lower mean absolute prediction error (MAE) and median absolute prediction error (MedAE) of 0.42 D to 0.45 D and 0.33 D to 0.36, and higher percentage of prediction error (PE) within ± 0.50 D (65.46%-67.87%). Regarding short eyes, the Haigis formula showed the lowest MedAE of 0.34 D and the highest percentage of PE within ± 0.50 D (68.42%) with no statistical difference, and satisfactory accuracy was achieved using all formulas (all p > 0.05). All formulas displayed better accuracy in medium eyes with lower MAE (0.41 D to 0.46 D), lower MedAE (0.33 D to 0.37 D), and higher percentage of PE within ± 0.50 D (62.42%-69.09%) except for Hoffer Q. Both EVO and BUII formulas revealed higher accuracy in long eyes with lower MAE (0.38 D to 0.41 D), lower MedAE ranging from 0.31 D to 0.33 D, and higher percentage of PE within ± 0.50 D of both 71.74%. CONCLUSIONS: The 4 new-generation formulas showed higher accuracy overall, and higher accuracy was achieved using EVO and BUII formulas in long eyes. All formulas revealed satisfactory accuracy in short eyes. All formulas displayed better accuracy in medium eyes except for Hoffer Q.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of 11 intraocular lens power calculation formulas in short eyes.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Accuracy of Intraocular Lens Power Calculation Formulas for Two Single-Piece Acrylic IOL Models in Eyes with a Shallow Anterior Chamber.Bioengineering (Basel, Switzerland) · 2026
- Comparison of the Accuracy of the Web-Based ESCRS IOL Power Calculator Formulas.Seminars in ophthalmology · 2026
- Comparison of IOL power calculation formulas in short eyes using ESCRS calculator and eyetemis: Influence of anterior segment biometry.PloS one · 2026
- Comparison of Prediction Accuracy of Six Toric IOL Power Calculation Formulas, Including Four Available on the ESCRS Online Calculator.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Biometry-Guided IOL Formula Selection in Post-Laser Vision Correction Eyes.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026