Multidimensional Modeling to Improve Intraocular Pressure Estimation in Glaucoma.
Oscar Albis-Donado, Lucrecia Berganza-Canales
Visual Sense, Private Practice, Mexico City, Mexico.
Key points
From the paper's conclusion- Multidimensional modeling improved agreement with DCT, with the dynamic component providing the greatest improvement in precision. Further validation in independent populations and at different altitudes is needed.
Abstract
PRECIS: A scalable multidimensional framework integrating environmental, structural, geometric, and dynamic information substantially improved agreement with dynamic contour tonometry compared with traditional corneal thickness-based correction methods. PURPOSE: To develop and evaluate a multidimensional framework for estimating intraocular pressure (IOP) in glaucoma eyes using dynamic contour tonometry (DCT) as the reference method. METHODS: This retrospective analysis included 94 eyes from 47 patients in a model-development cohort (MDC) and 40 eyes from 20 patients in a temporal validation cohort (VC). DCT, Goldmann applanation tonometry (GAT), rebound tonometry (iCare TA01), and keratometry were obtained at 2.49 km. Environmental, structural, geometric, and dynamic components were incorporated. Geometric and dynamic coefficients were optimized in the MDC and applied to the VC. Agreement with DCT was assessed using bias, mean absolute deviation (MAD), Bland-Altman limits of agreement (LoA), and proportional-bias analysis. RESULTS: In the MDC, DCT-GAT bias was 3.05 mm Hg (MAD 3.19; LoA width 7.57). The environmental-structural model reduced bias to -0.70 mm Hg. Adding geometry produced a bias of -0.51 mm Hg and LoA width of 8.06 mm Hg, whereas adding the dynamic component produced a bias of -0.91 mmHg, MAD 1.57, and LoA width 6.89 mm Hg. The integrated model showed a bias of -0.72 mm Hg, MAD 1.51, and LoA width 7.21 mm Hg. In the VC, integrated-model bias was -0.58 mm Hg, MAD 1.39, and LoA width 6.33 mm Hg. CONCLUSIONS: Multidimensional modeling improved agreement with DCT, with the dynamic component providing the greatest improvement in precision. Further validation in independent populations and at different altitudes is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Precision and reliability in tonometry: Comparison of Corvis ST and iCare in glaucoma patients on the Ecuadorian coast.Journal francais d'ophtalmologie · 2026
- Clinical evaluation of corneal elasticity and true IOP using a dual-applanation tonometerFrontiers in Ophthalmology · 2026
- In-office and remote intraocular pressure metrics associated with visual field progression in treated open-angle glaucoma.Ophthalmology · 2026
- Comparison of Intraocular Pressure Measurements Using iCare Rebound Tonometry and Goldmann Applanation Tonometry: A Systematic Review and Meta-Analysis.Journal of glaucoma · 2026
- Agreement between iCare HOME and Goldmann applanation tonometry: systematic review and meta-analysis.Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2026
- Differences in intraocular pressure measurements by tonometer type in children with glaucoma and suspected glaucoma.Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2026