科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Retina (Philadelphia, Pa.)2026-09-23

First-in-Human Implantation of an Add-On Dual Intraocular System Combining a Standard IOL and the SING-IMT™ Telescope: Optical Simulation, Preclinical Validation, and Clinical Feasibility.

Stanislao Rizzo, Paola Sasso, Irene Nepita, Giuseppe Francione, Carmela G Caputo, Mariantonia Ferrara, Alessandro Feo, Alfonso Savastano, Faustino Vidal-Aroca, Vladimir Belousov, Mario R Romano

一句话结论 · In one sentence

This integrated evaluation supports the feasibility and short-term safety of sulcus-based SING-IMT implantation as a minimally invasive intraocular magnification strategy for selected pseudophakic patients with advanced AMD.

原始摘要(英文原文)· Original abstract
PURPOSE: To evaluate a dual-implant system combining a capsular-bag monofocal intraocular lens with a sulcus-implanted small-incision new-generation implantable miniature telescope (SING-IMT). METHODS: Optical simulations quantified retinal spot size, modulation transfer function (MTF), and tolerance to misalignment. Preclinical porcine experiments evaluated surgical feasibility, anatomical stability, and early safety. First-in-human (FiH) implantation assessed surgical outcomes, anterior segment behaviour using ultrasound biomicroscopy and optical coherence tomography, functional vision, and safety over 6 months. RESULTS: Optical modelling demonstrated that the dual-implant configuration maintained retinal image quality within the rehabilitative regime for advanced AMD, with root-mean-square retinal spot radii of 18.7 µm (0°) and 20.4 µm (2.5°), below the estimated retinal sampling limit (∼49 µm), consistent with an expected visual acuity improvement of approximately 2 Snellen lines. Decentration up to 0.5 mm was optically well tolerated, whereas tilt produced rapid mid-frequency contrast loss. In vivo porcine studies confirmed stable sulcus seating without disruption of the capsular-bag IOL or anterior segment structures. FiH implantation was completed without intraoperative complications. At 6 months, distance visual acuity improved from 20/200 to 20/125, near acuity from 56 to 15 Colenbrander units, and reading speed from non-assessable preoperatively to 20 words/min, with no device-related adverse events. CONCLUSION: This integrated evaluation supports the feasibility and short-term safety of sulcus-based SING-IMT implantation as a minimally invasive intraocular magnification strategy for selected pseudophakic patients with advanced AMD.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

First-in-Human Implantation of an Add-On Dual Intraocular System Combining a Standard IOL and the SING-IMT™ Telescope: Optical Simulation, Preclinical Validation, and Clinical Feasibility. — 科研速览 Science Skim