Comparison of 19-gauge FNA and 22-gauge FNB needles for the EUS-guided fine-needle aspiration of the lymphadenopathy and malignant lymphoma diagnosis: A multicenter retrospective study.
Mitsuru Okuno, Shinya Uemura, Tsuyoshi Mukai, Fumiya Kataoka, Keisuke Iwata, Ryuichi Tezuka, Yuhei Iwasa, Takuya Koizumi,
Department of Gastroenterology, Matsunami General Hospital, Gifu, Japan. · First Department of Internal Medicine, Gifu University Hospital, Gifu, Japan.
Key points
From the paper's conclusion- The use of 19-gauge FNA needles appeared to be a good option for diagnosing lymphadenopathy, considering that no significant difference was observed in the occurrence of adverse events.
Abstract
BACKGROUND AND OBJECTIVES: EUS-guided fine-needle aspiration (EUS-FNA) using a 19-gauge FNA needle can safely obtain sufficient tissue samples for the evaluation of lymphadenopathy. FNB needles can also provide adequate tissue, and 22-gauge needles are generally easier to puncture than 19-gauge needles. This study aimed to compare the diagnostic performance of 19-gauge FNA and 22-gauge FNB needles for the diagnosis of lymphadenopathy. METHODS: Among the 411 patients with lymphadenopathy, 221 underwent an EUS-FNA procedure using 19-gauge FNA or 22-gauge FNB needles. Patient characteristics, puncture procedures, and the accuracy of the cytological and histological diagnoses of lymphadenopathy were analyzed. RESULTS: There were 116 and 105 patients in the 19-gauge FNA and 22-gauge FNB groups, respectively. The median lymph node size was significantly larger in the 19-gauge FNA group (29 mm vs. 23 mm, P < 0.01). Cytological and histological accuracies were significantly higher in the 19-gauge FNA group (91% vs. 63%, P < 0.01; 93% vs. 82%, P = 0.01). Multivariate logistic regression analysis showed that the use of 19-gauge FNA was significantly associated with diagnostic accuracy (cytology: odds ratio = 5.72, P < 0.01; histology: odds ratio = 3.38, P < 0.01). For malignant lymphoma diagnosis, immunohistochemical evaluation rates were similar between groups, whereas flow cytometry and cytogenetic sensitivities were significantly higher with 19-gauge FNA (90% vs. 55%, P < 0.01; and 68% vs. 14%, P < 0.01). Post-puncture infection was observed in only 1 patient in the 19-gauge FNA group. CONCLUSION: The use of 19-gauge FNA needles appeared to be a good option for diagnosing lymphadenopathy, considering that no significant difference was observed in the occurrence of adverse events.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Endobronchial Ultrasound-Guided Fine Needle Biopsy in the Diagnosis of Mediastinal Lymphadenopathy: A Randomized Trial.Journal of bronchology & interventional pulmonology · 2026
- Comparison of diagnostic performance of 19-gauge versus 22-gauge fine-needle biopsy needles for endoscopic ultrasound-guided liver biopsy: a systematic review and meta-analysis.European journal of gastroenterology & hepatology · 2026
- A paired comparative analysis of ultrasound-guided fine-needle aspiration and core-needle biopsy in malignant lymph nodes: Implications for clinical practice.Journal of cancer research and therapeutics · 2026
- Distributed Sample Allocation for the Diagnosis of Mass Lesions by EUS-FNA: A Prospective, Multicenter, Randomized Controlled Study.Journal of clinical gastroenterology · 2026
- Predicting ICG fluorescence uptake in laparoscopic lymphoma biopsy: the role of a 20 mm node size cut-off.Updates in surgery · 2026
- Diagnostic spectrum and cytomorphological features of 1,641 pancreatobiliary EUS-FNA specimens: a five-year retrospective study from a central cytopathology laboratory serving 14 hospitals.Frontiers in medicine · 2026