A paired comparative analysis of ultrasound-guided fine-needle aspiration and core-needle biopsy in malignant lymph nodes: Implications for clinical practice.
Qinxian Zhao, Zhonghua Yue, Fengyi Yu, Fengxia Hu, Huihui Niu, Hui Wang, Xincun Zhang, Zhen Wang
Department of Special Inspection, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China.
Key points
From the paper's conclusion- CNB exhibits superior sensitivity over FNAB for malignant lymphadenopathy. On the contrary, the combined approach adds minimal benefit (+0.52%), and it is not justified for routine use. Thus, CNB should be the preferred first-line biopsy method.
Abstract
PURPOSE: This study aimed to compare the diagnostic sensitivity of ultrasound-guided fine-needle aspiration biopsy (FNAB), core-needle biopsy (CNB), and their combination in malignant superficial lymph nodes while identifying key influencing factors. MATERIALS AND METHODS: A total of 390 patients with malignant superficial lymph nodes undergoing simultaneous FNAB and CNB were included in this retrospective study. Sensitivity and false-negative rates were calculated for each method. McNemar's test was used for pairwise comparisons, and factors associated with false-negative results were analyzed via logistic regression. RESULTS: The overall sensitivity reached 89.23% for FNAB, 96.92% for CNB, and 97.44% for the combined approach. In particular, CNB showed significantly higher sensitivity than FNAB, especially in lymphoma (100% versus 51.52%) and lymph nodes >3 cm (98.46% versus 86.15%). By contrast, the combined strategy showed only a marginal increase in sensitivity (+0.52%). McNemar's test revealed 32 FNAB false negatives versus two CNB false negatives ( P < 0.001). The longitudinal-to-transverse diameter ratio was an independent predictor of false negatives for both methods (FNAB: OR 0.26, P < 0.01; CNB: OR 0.21, P < 0.01). CONCLUSION: CNB exhibits superior sensitivity over FNAB for malignant lymphadenopathy. On the contrary, the combined approach adds minimal benefit (+0.52%), and it is not justified for routine use. Thus, CNB should be the preferred first-line biopsy method.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The preanalytical phase in hematopathology: sampling as a critical step for an appropriate diagnosis. A position paper from the Italian Group of Haematopathology (GIE).Haematologica · 2026
- Diagnostic accuracy of core needle biopsy versus fine-needle aspiration cytology in salivary gland malignancies: A systematic review and metaanalysis.Clinical and experimental otorhinolaryngology · 2026
- Core Needle Biopsy in the Diagnosis of Major Salivary Gland Tumors.The Laryngoscope · 2026
- Clinical Applicability of the WHO Reporting System for Axillary Lymph Node Fine-Needle Aspiration in Invasive Breast Carcinoma.Cancers · 2026
- Diagnostic performance and timeliness of ultrasound-guided core needle biopsy for peripheral lymphadenopathy in Internal Medicine: a multicenter real-world study.Internal and emergency medicine · 2026
- Diagnostic Accuracy of Multiparametric Ultrasound Versus Cross-Sectional Imaging for Differentiating Benign and Malignant Cervical Lymph Nodes: A Histopathology-Referenced Retrospective Study.Diagnostics (Basel, Switzerland) · 2026