Comparison of diagnostic performance of 19-gauge versus 22-gauge fine-needle biopsy needles for endoscopic ultrasound-guided liver biopsy: a systematic review and meta-analysis.
Aamir Saeed, Jessica Perry, Jiten Kothadia, Hina Akbar, Claudio R Tombazzi, Janak Shah, Leonard Baidoo, Mansour A Parsi,
Division of Gastroenterology and Hepatology, University of Tennessee Health Sciences Center, Memphis, Tennessee, USA. · Department of Medicine, King Edward Medical University, Lahore, Pakistan.
Key points
From the paper's conclusion- In conclusion, this meta-analysis demonstrates that most of the outcomes of EUS-LB were comparable between the 19G and 22G needle groups, except ASL and length of the longest fragment, which were longer in the 19G group.
Abstract
Studies have compared 19-gauge (19G) and 22G needles for endoscopic ultrasound-guided liver biopsy (EUS-LB) and reported variable results. We conducted a meta-analysis to compare the outcomes of EUS-LB with 19G vs. 22G needles. We reviewed several databases from inception to 19 October 2025. Outcomes of interest were diagnostic yield, tissue adequacy, adverse events, complete portal tracts (CPTs), aggregate specimen length (ASL), and length of the longest fragment. Data were analyzed using a random-effects model. We found no significant difference in diagnostic yield [risk ratio: 1.11, 95% confidence interval (CI): 0.93-1.32], tissue adequacy (risk ratio: 1.47, 95% CI: 0.87-2.49), and adverse events (risk ratio: 1.22, 95% CI: 0.38-3.96) between groups. We found no significant difference in mean CPTs between groups. Mean ASL and length of the longest fragment were significantly longer in the 19G group. In conclusion, this meta-analysis demonstrates that most of the outcomes of EUS-LB were comparable between the 19G and 22G needle groups, except ASL and length of the longest fragment, which were longer in the 19G group.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Randomized Controlled Trial of Endoscopic Ultrasound‐Guided Liver Biopsy Versus Percutaneous Liver Biopsy for Obtaining Histologically Adequate SpecimensJournal of Gastroenterology and Hepatology · 2026
- Endoscopic ultrasound-guided biopsy using a 19-gauge Franseen needle versus percutaneous ultrasound-guided biopsy using an 18-gauge full-core cutting needle for parenchymal liver disease: a randomized, controlled, noninferiority trial.Gastrointestinal endoscopy · 2026
- Diagnostic yield of Franseen biopsy needles in endoscopic ultrasound-guided tissue acquisition: a systematic review and meta-analysis.PeerJ · 2026
- Diagnostic performance and safety of EUS-guided liver biopsy: A multicenter Latin American comparative study.Endoscopic ultrasound · 2026
- Rapid versus slow puncture in endoscopic ultrasound-guided liver biopsy: a multicenter randomized crossover trial.Endoscopy · 2026
- Comparison of 19-gauge FNA and 22-gauge FNB needles for the EUS-guided fine-needle aspiration of the lymphadenopathy and malignant lymphoma diagnosis: A multicenter retrospective study.Endoscopic ultrasound · 2026