Regulatory survey of ambient dose equivalent rates around baggage scanners in Tanzania.
Atumaini A Makoba, Mikidadi S Gurisha, Julius S Chiuyo, Innocent J Lugendo
Department of Physics, University of Dar es Salaam, P.O. Box 35063, Dar es Salaam, Tanzania. · Tanzania Atomic Energy Commission, P.O. Box 1585, Plot No. 634, Block AF, 2 Atomu Road, Kikombo Area, 41206 Dodoma, Tanzania.
Key points
From the paper's conclusion- This study assessed ambient dose equivalent rates (H* (10)) around baggage scanners at selected airports, ports, and commercial facilities.
Abstract
The deployment of baggage scanners in airports and public facilities requires periodic radiation surveys to ensure occupational safety and regulatory compliance. This study assessed ambient dose equivalent rates (H* (10)) around baggage scanners at selected airports, ports, and commercial facilities. Measurements were taken at: 1 m from the entry and exit points, 2 m from the scanner, and the control panel. Measured dose rates ranged from 0.02 to 0.55 μSv/h, with the highest values near the entry and exit openings. Dose rates at operator positions were generally ≤0.10 μSv/h, comparable to background levels. Conservative annual effective dose ranged from 0.28 to 4.22 mSv/year. Realistic occupancy scenarios indicated that most operators received <1 mSv/year. Estimated doses were below the 20 mSv/year recommended by international standards. These results confirm adequate radiation safety margins in Tanzanian facilities. Continued routine monitoring and personal dosimetry are recommended to maintain compliance and protect workers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integrated spatiotemporal assessment of ambient radiation fields in a nuclear medicine department using OSL and time-resolved Geiger-Müller monitoring.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Environmental radiological baseline characterization of a proposed medical cyclotron facility in Indonesia using dual-detector measurements and geostatistical analysis.Environmental geochemistry and health · 2026
- Analysis of Terrestrial Nuclear Radiation Dose Rate Distribution in Kotamobagu CityJournal of Physics: Conference Series · 2026
- Radiation Protection Practices in Classified Versus Non-Classified Areas of X-Ray Units in Jos Plateau StateNigerian Journal of Physics · 2026
- Preliminary Radiological Dose Assessment: A Case Study of Tourist Caves in Pacitan, IndonesiaEnvironments · 2026
- Operator-induced reduction of air kerma during backpack-based gamma-ray measurement.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026