Revealing the osseointegration potential of Mg-based implants: A multilevel comparison of ZX00, PLGA and titanium screws in an ovine preclinical model
Suljevic Omer, Weigl Valentin, Stahle Christopher, Schwarze Uwe Yacine, Szyszko Mertelseder Ilona, Marek Romy Linda, Ristanovic Dragan, Spuller Mirjam,
Key points
From the paper's conclusion- Here we investigated the osseointegration, biocompatibility, degradation, performance and biomechanical properties of a Mg-based alloy (ZX00) over 26 weeks (w) in comparison to absorbable poly-L-lactic-co-glycolide acid (PLGA) and state-of-the-art titanium (Ti), implanted into an ovine model.
Abstract
Absorbable materials like polymers and magnesium (Mg) exhibit promising characteristics as orthopedic implants. Mg-based implants offer bone-like mechanical properties with an adequate osteogenic potential and a stable degradation pattern. Here we investigated the osseointegration, biocompatibility, degradation, performance and biomechanical properties of a Mg-based alloy (ZX00) over 26 weeks (w) in comparison to absorbable poly-L-lactic-co-glycolide acid (PLGA) and state-of-the-art titanium (Ti), implanted into an ovine model. ZX00, PLGA, and Ti screws were bicortically implanted into the tibiae of 33 sheep. To assess implant behavior, we performed in vivo X-ray imaging and computed tomography (CT) and ex vivo high-resolution µCT. Furthermore, systemic and local biocompatibility was investigated by histology. Novel push-out biomechanical testing complemented the osseointegration assessment. We observed close bone-to-implant contact across all groups and progressive degradation of ZX00 implants accompanied by increased cortical bone apposition, also observed in the PLGA and Ti groups. Osseointegration and biocompatibility of ZX00 implants were observed with no signs of systemic toxicity comparable to PLGA or Ti. Biomechanical testing demonstrated consistency in force required to push out ZX00 screws. ZX00 was comparable to PLGA and Ti implants regarding osseointegration, mechanical stability and biocompatibility. This study demonstrates that ZX00 combines progressive degradation with sustained osseointegration and functional fixation stability, making it an appropriate absorbable alternative in orthopedic surgery and providing new insight into the relationship between degradation, biological response and implant stability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-term evaluation of plasma electrolytic oxidation (PEO) surface-modified WE43MEO magnesium alloy screws and plates reveals safe and controlled degradation in a 18-month minipig modelJournal of Orthopaedic Translation · 2026
- Rare-earth-free magnesium-zinc alloy with controlled biodegradation and biocompatibility for novel biodegradable metallic stent.Biomaterials · 2026
- Biofunctional Testing of a Degradable Implant Made by Mg-Nd and Mg-Zn Alloys Used for Bone DefectsBiomimetics · 2026
- Biodegradable Magnesium-Based Implants in Sports Orthopedic Surgery: Advances in Alloy Design, Surface Engineering, and Translational Evidence.Bioengineering (Basel, Switzerland) · 2026
- Region-dependent in vivo degradation and local repair responses of a magnesium artificial lamina in a rabbit lamina defect model.Acta biomaterialia · 2026
- Alloy design strategies for biodegradable magnesium implants: Linking composition, microstructure, and degradation controlJournal of Materials Research and Technology · 2026