School of Material Science and Engineering, Zhongyuan Critical Metals Laboratory, Zhengzhou University, Zhengzhou, 450001, China. · School of Material Science and Engineering, Zhongyuan Critical Metals Laboratory, Zhengzhou University, Zhengzhou, 450001, China; Henan Key Laboratory of Advanced Light Alloys, Zhengzhou 450002, China. Electronic address: wangj@zzu.edu.cn.
Key points
From the paper's conclusion- Thus, faster magnesium degradation does not necessarily improve repair.
Abstract
Magnesium (Mg)-based implants are promising for lamina defect reconstruction because of their biodegradability, mechanical compatibility, and bioactivity. However, in vivo degradation is usually assessed at the whole-implant level, and it remains unclear whether distinct regions of the same implant experience different degradation-repair couplings. In this study, a ZE21C Mg alloy artificial lamina was implanted in a New Zealand rabbit lumbar lamina defect reconstruction model to evaluate region-dependent degradation and local repair responses. Finite element analysis showed higher equivalent stress and strain on the residual-bone side. SEM/EDS and micro-CT analyses demonstrated the asymmetric degradation of the same implant in vivo. The residual-bone side exhibited faster Mg degradation, more severe surface and interfacial degradation, and higher TRAP-related remodeling activity, whereas the opposite side degraded more slowly, maintained a denser interface, and exhibited better bone formation and tissue integration. At 12 weeks, the remaining implant volume was 20.2 ± 2.0% on the residual-bone side, compared with 41.9 ± 5.3% on the opposite side, demonstrating pronounced region-dependent degradation within the same implant. Transcriptomic analysis indicated that rapid degradation was accompanied by stronger bone resorption and inflammatory interface reactions. The slow degradation area is associated with a more vascularized repair microenvironment that supports the matrix. These findings indicate that accelerated regional degradation does not necessarily promote bone regeneration. Therefore, region-specific degradation control may be critical for designing biodegradable Mg implants in complex anatomical environments. STATEMENT OF SIGNIFICANCE: Biodegradable magnesium implants are generally evaluated by their average degradation rate, despite regional differences in mechanical and biological environments. In a rabbit lamina reconstruction model, we directly compared two regions of the same ZE21C magnesium artificial lamina, limiting implant- and animal-level variability. The residual-bone side experienced higher stress, faster degradation, a less stable interface, stronger osteoclast-related activity, and poorer bone formation; the opposite side degraded more slowly and supported better tissue integration. Transcriptomic analysis linked these outcomes to distinct inflammatory, bone-resorptive, vascular, and matrix-remodeling responses. Thus, faster magnesium degradation does not necessarily improve repair. This work identifies region-specific degradation control as a key design principle for biodegradable orthopedic implants in complex anatomical environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Magnesium-containing implants enhance bone healing: A mechanobiological perspectiveMechanobiology in Medicine · 2025
- Mg Ion Diffusion at in Vivo Bone-Mg-10Gd Implant Interface Revealed by Atom Probe Tomography.Acta biomaterialia · 2026
- Biological Evaluation of Two Magnesium Alloys from Mg-Zn-Mn-Ca and Mg-Nd-Y-Zr-Zn Systems for Bone Repair and Regeneration.Journal of functional biomaterials · 2026
- Biofunctional Testing of a Degradable Implant Made by Mg-Nd and Mg-Zn Alloys Used for Bone DefectsBiomimetics · 2026
- Revealing the osseointegration potential of Mg-based implants: A multilevel comparison of ZX00, PLGA and titanium screws in an ovine preclinical modelRegenerative Biomaterials · 2026
- Alloy design strategies for biodegradable magnesium implants: Linking composition, microstructure, and degradation controlJournal of Materials Research and Technology · 2026