EP03.38 Temporal improvement in image acquisition quality and concordance using intraoperative confocal laser endomicroscopy in brain tumors
L Bauluz, S Marcos, V García-Milán, R Martín-Láez, C Velásquez
Key points
From the paper's conclusion- Therefore, we aimed to evaluate temporal trends in image quality, acquisition efficiency, and concordance with histopathology.
Abstract
Background Confocal laser endomicroscopy (CLE) enables real-time intraoperative tissue assessment in neuro-oncology. However, its clinical performance might depend on image acquisition quality and operator experience, often resulting in a substantial proportion of non-interpretable images. Therefore, we aimed to evaluate temporal trends in image quality, acquisition efficiency, and concordance with histopathology. Material and Methods We retrospectively analyzed consecutive patients undergoing surgery for high-grade intra-axial tumors, including glioblastoma and brain metastases, between June 2023 and January 2026. A subgroup of patients with paired CLE imaging and histopathology was included . Temporal trends were assessed by year, focusing on image quality (motion- and blood-related artifacts), proportion of non-interpretable images, proportion of useful images, number of images per case, and concordance with histopathology. Results A total of 29 cases were included. Image acquisition quality improved over time, with a decrease in motion-related artifacts despite an initial increase (10.5% in 2023, 15.8% in 2024, and 4.3% in 2025), while blood-related artifacts showed a slight increase and subsequent stabilization (6.0% in 2023, 8.3% in 2024, and 8.3% in 2025). The proportion of useful images increased overall (48% [n = 39] in 2023, 46% in 2024 [n = 37], and 66% [n = 41] in 2025). The number of images per case initially increased and subsequently decreased (mean 320 in 2023, 520 in 2024, and 270 in 2025), suggesting improved acquisition efficiency. Concordance between CLE and histopathology also improved over time, with a reduction in discordant cases (n = 4 in 2023, n = 2 in 2024, and n = 0 in 2025). These findings reflect progressive optimization of both image acquisition and interpretation in clinical practice. However, histopathological sampling was not blinded to CLE findings, introducing potential selection bias and limiting formal accuracy estimation. Conclusion CLE performance improves over time, with measurable gains in image quality, efficiency, and concordance with histopathology, despite a reduction in the number of images acquired per case. These findings support the integration of CLE into routine neuro-oncological surgery, although prospective studies with blinded sampling are required to establish its diagnostic accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- OS13.5.A Prospective Multicenter Clinical Trial for Rapid Intraoperative Diagnosis and AI Augmented Evaluation of Brain Tumors Using ICG induced Confocal Laser EndomicroscopyNeuro-Oncology · 2026
- OS13.7.A Confocal laser endomicroscopy outperforms white light and sodium fluorescein for tumour margin assessment in glioma surgery: the Florence experienceNeuro-Oncology · 2026
- Initial Experience with Confocal Laser Scanning Microscopy for Intraoperative Margin Assessment During Robot-Assisted Radical Prostatectomy.Journal of endourology · 2026
- OS13.6.A Delineation of the infiltration zone using intra-operative laserendomicroscopy in patients with glioblastomaNeuro-Oncology · 2026
- Qualitative and quantitative assessment of ex vivo human brain tumors using quantitative oblique back-illumination microscopy (qOBM)Biomedical Optics Express · 2026
- Real-time in vivo optical imaging of glioma with confocal laser endomicroscopy in a murine model: comparative analysis of performance of indocyanine green and fluorescein sodium.Frontiers in oncology · 2026