Neuro-Oncology

RADT-46 Evaluation of brain stereotactic radiosurgery plan quality using a dual-model deep learning framework: a cross-platform analysis

Ryan Shah, Zhenghao Xiao, Wenchao Cao, Griffin O’Neill, Mariah Bloomfield, Ankith Alluri, Wenyin Shi, Yingxuan Chen,

Computational · n=155

Key points

From the paper's conclusion
  • This framework provides an objective tool for standardized, cross-platform evaluation of SRS dose falloff.

Abstract

Background Cross-platform evaluation of stereotactic radiosurgery (SRS) plan quality remains challenging due to the lack of standardized reference dose distributions. We evaluated whether a dual-model deep learning framework could generate benchmarks for quantifying dose falloff across Gamma Knife (GK), CyberKnife (CK), and LINAC-based Dynamic Conformal Arcs (DCA) and Volumetric Modulated Arc Therapy (VMAT). Methods We retrospectively evaluated 325 intracranial targets in 155 patients treated with GK (60 patients, 65 targets), CK (29 patients, 52 targets), DCA (37 patients, 137 targets), or VMAT (29 patients, 71 targets). Target volumes ranged from 0.04 to 28.8 cc (median 0.5 cc). For each target, benchmark dose distributions were generated by an in-house deep learning framework with two U-Net models trained to predict optimal dose falloff for small (<1 cc) and large (≥1 cc) targets. Single-fraction clinical plans were evaluated against benchmarks using Brain Sparing Index (BSI) and whole-brain V12Gy difference. For each target, BSI is the ratio of area under the benchmark dose-volume curve to area under the clinical dose-volume curve. Results Median BSI was 0.65 (IQR 0.52-0.81) for DCA, 0.53 (IQR 0.28-0.69) for VMAT, 0.52 (IQR 0.45-0.64) for CK, and 0.50 (IQR 0.39-0.66) for GK. VMAT exhibited target size-associated differences, with a median small-target BSI of 0.41 (IQR 0.25-0.59) and median large-target BSI of 0.72 (IQR 0.60-0.79). Whole-brain V12Gy for clinical plans exceeded benchmark distributions by a median of 0.7 cc (IQR 0.3-1.4 cc) for GK, 0.9 cc (IQR 0.4-1.9 cc) for VMAT, 1.0 cc (IQR 0.5-3.2 cc) for DCA, and 1.6 cc (IQR 1.0-3.6 cc) for CK. Conclusions The deep learning framework provided consistent, patient-specific dosimetric goals with superior peri-target dose falloff for all modalities. Modality-associated differences may reflect current dataset characteristics, as doses were not re-normalized. This framework provides an objective tool for standardized, cross-platform evaluation of SRS dose falloff.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers