Prescription-aware diffusion Transformer for esophageal VMAT dose prediction: a retrospective dual-center validation and target-level analysis
Jiacheng Guo, Yue Wang, Xiaoyun Huang, Liu Wang, Qinmei Liao, Jinwei Hu, Xihao Hu, Xiaojia Yu,
Key points
From the paper's conclusion- We developed a prescription-aware diffusion Transformer framework for esophageal VMAT dose prediction and evaluated voxel-wise prediction accuracy, prescription-specific target behavior, and target-integrity sensitivity in a dual-center cohort.
Abstract
Background Deep learning-based radiotherapy dose prediction has the potential to support automated treatment planning and plan-quality assessment; however, simultaneous integrated boost (SIB) volumetric modulated arc therapy (VMAT) for esophageal cancer remains challenging because multiple target levels are associated with different prescription doses and complex spatial relationships. We developed a prescription-aware diffusion Transformer framework for esophageal VMAT dose prediction and evaluated voxel-wise prediction accuracy, prescription-specific target behavior, and target-integrity sensitivity in a dual-center cohort. Results The global MAE within the body/union PTV MAE of DoseDiT was 3.15/4.79 Gy in the validation set, 3.07/4.99 Gy in the internal test set, and 4.25/7.47 Gy in the external test set. Target-level analysis revealed a systematic prescription-dependent bias, characterized primarily by persistent underestimation of D95/Rx for Boost targets in both the internal and external cohorts. After RxMap ablation, the PTV MAE increased to 5.35 Gy internally and 8.17 Gy externally, supporting the value of voxel-wise prescription representation for modeling complex target-dose distributions. GlobalPSDM provided no additional accuracy gain, whereas the MMFNet baseline under matched settings achieved lower errors. These findings indicate that the principal value of this study lies in prescription-aware representation and target-level error characterization. Conclusion The voxel-wise RxMap provides local prescription-level information for SIB treatment plans, with its contribution concentrated primarily within target regions. Target-level analysis further demonstrated a systematic prescription-dependent coverage bias, with underestimation of Boost coverage showing good reproducibility in both the internal and external cohorts. GlobalPSDM did not provide an additional prediction-accuracy gain in the current implementation, whereas the matched MMFNet baseline achieved lower values for the major error metrics. These findings indicate that heterogeneous-prescription dose prediction should consider local prescription representation, target-level evaluation, and cross-center model robustness simultaneously. The current DoseDiT can serve as a research-oriented dose prior and analytical framework; further clinical translation will require three-dimensional or physics-aware modeling and prospective multicenter validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Learning the Dose Manifold: A Latent Diffusion Framework for Volumetric Dose Prediction in Automated Radiotherapy Treatment PlanningarXiv · 2026
- From Predicted Dose to Computationally Verified Plan: An End-to-End Deep Learning and Monte Carlo Pipeline for Automated VMAT Glioblastoma Radiotherapy.Journal of imaging informatics in medicine · 2026
- Enhanced diffusion model with 3D structural and segmentation priors for lung cancer radiotherapy dose prediction.Physics in medicine and biology · 2026
- DoseSteer: Steering diffusion-based dose prediction models towards clinical targets via Dual-Response GuidancearXiv · 2026
- A virtual physicist framework integrating dose prediction and large language models for automated treatment planning.Journal of applied clinical medical physics · 2026
- Clinical DVH metrics as a loss function for 3D dose prediction in head and neck radiotherapy.International journal of computer assisted radiology and surgery · 2026