Sensor Design for Ankle Resiliency Training.
Ashwin Iyer, Amy Silder, Hunter Lassard, Serge H Roy, Gianluca De Luca, Joshua Kline, John P Chiodini
Altec Inc, Natick, MA 01760, United States. · Warfighter Performance Department, Naval Health Research Center, San Diego, CA 92152, United States.
Key points
From the paper's conclusion- Our work describes the design of ARES by integrating sEMG hardware and signal processing algorithms into a tool to assess PL workload during functional exercises. Results show an ability to robustly differentiate between crosstalk and PL activity highlighting potential utility to assist in injury-prevention or rehabilitation outcomes.
Abstract
INTRODUCTION: Lateral ankle sprains (LASs) are among the most common musculoskeletal injuries and are a leading cause of limited duty days among service members. Rehabilitation and prevention strategies focus on strengthening the peroneus longus (PL) muscle as a protection mechanism, however clinical assessments of PL engagement during training are qualitative and require expert evaluation. Existing surface electromyography (sEMG) technologies allow noninvasive estimations of muscle activation, but are limited when energy from neighboring muscles (crosstalk) reaches detection sites at anatomically constrained muscles like the PL. To address this gap, we introduce the Ankle REsiliency System (ARES), a hardware-software platform that integrates high-density sEMG with custom signal processing algorithms to isolate and quantify PL workload during functional exercises. MATERIALS AND METHODS: ARES consists of a high density sEMG electrode array equipped with custom signal processing firmware and software which streams high fidelity sEMG data and quantifies PL workload during functional exercises. System validation was conducted with 5 healthy male participants (21-35 years). Algorithm validation was performed on isolated tasks of eversion and dorsiflexion, where PL workload estimates were compared against true labels provided by bipolar sEMG recordings. Full system validation was then performed during 5 biomechanically relevant exercises designed to challenge the PL across varying intensity levels. RESULTS: For isolated tasks, ARES achieved 93.3% ± 1.1% accuracy in distinguishing PL activity from crosstalk. During dynamic exercises, ARES detected workload increases between low and high force exercises (P < .05). CONCLUSIONS: Our work describes the design of ARES by integrating sEMG hardware and signal processing algorithms into a tool to assess PL workload during functional exercises. Results show an ability to robustly differentiate between crosstalk and PL activity highlighting potential utility to assist in injury-prevention or rehabilitation outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving the Clinical Utility of Lower-Limb Surface Electromyography (sEMG) by Quantifying and Correcting for Location Changes in Inter-Session Recordings.Annals of biomedical engineering · 2026
- Development and Validation of an Automated Pipeline for Motor Unit Analysis from HD-sEMG Signals.Sensors (Basel, Switzerland) · 2026
- An Intelligent Wearable EMG Sensing Framework for Athlete Neuromuscular Monitoring and Performance Progression Assessment.Biosensors · 2026
- Deep learning for motion classification in ankle exoskeletons using surface EMG and IMU signalsScientific Reports · 2025
- EMG Probability Density Function Inverse Problem: Motor Unit Potential Amplitude Versus Motor Unit Recruitment Threshold Maps.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- High-Density Surface Electromyography Detects Fiber-Type-Related Profiles and Disease-Relevant Fatigue Trajectories in Amyotrophic Lateral SclerosismedRxiv · 2026