Improving the Clinical Utility of Lower-Limb Surface Electromyography (sEMG) by Quantifying and Correcting for Location Changes in Inter-Session Recordings.
Fraser Douglas, Mona Pei, Quoc Sy Vu, Linh Le, Calvin Kuo
School of Biomedical Engineering, University of British Columbia, British Columbia, Canada. Fraser.Douglas@ubc.ca. · School of Biomedical Engineering, University of British Columbia, British Columbia, Canada.
Key points
From the paper's conclusion- The application of our algorithm effectively reduced inter-session feature differences arising from changes in electrode location. This approach can facilitate more direct cross-session feature comparisons, representing a promising step toward robust sEMG measurement for musculoskeletal and neurological recovery tracking.
Abstract
PURPOSE: Surface electromyography (sEMG) can enable direct muscle activity measurement to support the recovery assessment of individuals with neurological and musculoskeletal disorders. Despite this, its broader adoption of sEMG has been limited given its sensitivity to changes in electrode location across sessions. To address this challenge and enable multi-session sEMG, this work develops a novel high-density sEMG (HDsEMG) algorithm to quantify changes in electrode location and mitigate its effects on common time and frequency domain sEMG features. METHODS: 11 healthy participants performed isometric and dynamic exercises with HDsEMG on four lower-limb muscles. These were repeated four times, reapplying arrays at shifted locations. The error between spatially-mapped HDsEMG metrics was then minimised to estimate the change in array location, with this compared against ground truth 3D scans. Lastly, relative feature differences across locations were computed at select electrodes to assess the degree to which inter-session sEMG effects were mitigated. RESULTS: Electrode location estimates were improved over the assumption their location remained unchanged in 81.7% of cases, 37.6% identified within 1 cm of the ground truth. Feature differences computed between closest electrodes across locations per ground truth and algorithm estimates were statistically similar. Conversely, feature differences for the same electrode across locations were significantly greater, increasing the mean difference for the isometric max envelope amplitude from 15.9% with the algorithm to 21.1% without. CONCLUSIONS: The application of our algorithm effectively reduced inter-session feature differences arising from changes in electrode location. This approach can facilitate more direct cross-session feature comparisons, representing a promising step toward robust sEMG measurement for musculoskeletal and neurological recovery tracking.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fusion of Nine-Channel sEMG and Dual-IMU Sensors for Knee-Angle Estimation Based on CatBoost Feature Selection and Neuron-Level Attention LSTMBiosensors · 2026
- Low-Density sEMG Four-Finger Recalibration with Limited Calibration Data via Classwise Amplitude and Covariance Adaptation of Prior Training Data.Sensors (Basel, Switzerland) · 2026
- High-Density Surface Electromyography Detects Fiber-Type-Related Profiles and Disease-Relevant Fatigue Trajectories in Amyotrophic Lateral SclerosismedRxiv · 2026
- Sensor Design for Ankle Resiliency Training.Military medicine · 2026
- Robust decoding of hand movement for mitigating muscle contraction variability from surface EMG signals.Journal of neural engineering · 2026
- Development and Validation of an Automated Pipeline for Motor Unit Analysis from HD-sEMG Signals.Sensors (Basel, Switzerland) · 2026