EP9.25 The Effect of Suction Clamping on Noise Pollution in Hip Arthroscopy: A Randomized Control Trial
Dr Andrea Spiker, Megan Baughman, Dr Jake Enos, Jack Drake, Collin Nguyen, Taishi Ikeda, Dr Rachael Tolsma, Dr Brian Nickel
Key points
From the paper's conclusion- Purpose This study aimed to evaluate the effectiveness of suction clamping for mitigating noise pollution during hip arthroscopy and analyze the impacts of the corresponding noise levels on operating time.
Abstract
Purpose This study aimed to evaluate the effectiveness of suction clamping for mitigating noise pollution during hip arthroscopy and analyze the impacts of the corresponding noise levels on operating time. Methods Patients undergoing primary hip arthroscopy at a single institution by a single surgeon were randomized in a 1:1 ratio to intervention or control groups. In intervention group procedures, the bag suction was clamped when not in use. In control group procedures, the bag suction was left open. Sound levels were recorded throughout the case at the location of the primary surgeon, first assist, scrub technician, nurse, and anesthesia staff using microphones and the dB-Tester application. T-tests were used to compare the control group to the intervention groups and the various OR roles. Pearson correlations were used to look for correlation between average sound level and overall operative time. Results There was no significant difference in average sound level overall between the control (68.07 dB) and intervention (67.45 dB) groups (p=0.12, CI= [-0.17, 1.40]). Separated by OR role, there was again no significant difference in sound levels between the control and intervention groups (anesthesia p=0.41, first assist p=0.33, nurse p=0.68, scrub technician p=0.12, surgeon p=0.15). Microphones on the surgeon and first assist recorded significantly higher average dBs than all other OR staff (p-values <0.0001). There was no significant difference in proportion of operation spent above the NIOSH maximum sound threshold (85 dB) between the intervention in control groups (p=0.46). Average operative times between control and intervention groups were not significantly different (p=0.69). Within the control group, there was a significant positive correlation between operative time and average (r=0.20, p=0.042) and maximum (r=0.012, p=0.012) sound levels. Conclusion We found no significant difference in OR sound levels between procedures with suction clamping and those without. Sound levels positively correlated with operative time.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP9.23 Intraoperative Noise Exposure Across the Spectrum of Hip Surgery: Hip Arthroscopy, Periacetabular Osteotomy, and Total Hip ArthroplastyJournal of Hip Preservation Surgery · 2026
- Association between intraoperative noise intensity during hip arthroplasty and the postoperative risk of kinesiophobia: a prospective cohort study.Frontiers in surgery · 2026
- Effect of noise isolation with noise-cancelling earmuffs during laparoscopic surgery on acute postoperative pain: a clinical randomised controlled trialBMC Anesthesiology · 2025
- Occupational hazards in hip and knee adult reconstruction surgery : a systematic review of physical and psychological stressors.Bone & joint open · 2026
- Evaluation of bone-conducted sound during ear surgery: an in vivo pilot study.Biomedical engineering online · 2026
- Operating room noise levels in anaesthesia a systematic review and meta-analysis.British journal of anaesthesia · 2026