EP9.23 Intraoperative Noise Exposure Across the Spectrum of Hip Surgery: Hip Arthroscopy, Periacetabular Osteotomy, and Total Hip Arthroplasty
Collin Nguyen, Dr Jack Drake, Dr Matthew Hoffa, Dr Justin Lapow, Samuel Mosiman, Dr Brian Nickel, Dr Andrea Spiker
Key points
From the paper's conclusion- These findings are indicative of single case exposures, and repeated exposure across multiple cases per day and over years of practice may contribute to cumulative noise burden.
Abstract
Background Orthopaedic surgeons are exposed to substantial intraoperative noise, particularly during procedures involving powered instrumentation, reaming, broaching, and implant insertion. The OSHA defined permissible exposure limit is 90 dB over an 8-hour day and although prior studies have evaluated noise exposure in arthroplasty, comparative data across hip preservation and hip reconstructive procedures remain limited. This study compared intraoperative noise exposure during hip arthroscopy, periacetabular osteotomy (PAO), and total hip arthroplasty (THA). Methods A prospective observational study was performed at a single institution between January 2024 and October 2025. Consecutive cases were included. Sound meters were placed according to operating room role. Recordings began at incision and ended at skin closure. Primary outcomes were OSHA-derived noise dose percentage (Dose %) and time-weighted average exposure (TWA, dBA). Secondary outcomes included LAeq, RMS Max, and sound exposure level (SEL). Comparisons across procedures were performed using Kruskal-Wallis tests with Bonferroni-adjusted pairwise testing. One surgeon performed all THAs while another surgeon performed all hip arthroscopies and PAOs. Results Fifty-seven cases were successfully analyzed, including 20 hip arthroscopies, 17 PAOs, and 20 THAs. Mean recorded case duration was 69.0 ± 14.0 minutes for hip arthroscopy, 170.6 ± 34.9 minutes for PAO, and 31.5 ± 8.2 minutes for THA. Surgeon noise exposure was significantly greater during PAO and THA than during hip arthroscopy. Compared with hip arthroscopy, surgeons had higher Dose % during PAO (4.57 ± 1.53% vs 1.12 ± 0.57%; p < 0.001) and THA (3.56 ± 2.29% vs 1.12 ± 0.57%; p < 0.001), and higher TWA during PAO (67.34 ± 2.51 vs 56.59 ± 4.12 dBA; p < 0.001) and THA (63.90 ± 6.39 vs 56.59 ± 4.12 dBA; p < 0.001). Conclusions Surgeon cumulative noise exposure is significantly higher during PAO and THA than during hip arthroscopy. These findings support hip surgery as a meaningful occupational noise source and reinforce the need for targeted hearing conservation strategies. These findings are indicative of single case exposures, and repeated exposure across multiple cases per day and over years of practice may contribute to cumulative noise burden.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP9.25 The Effect of Suction Clamping on Noise Pollution in Hip Arthroscopy: A Randomized Control TrialJournal of Hip Preservation Surgery · 2026
- Association between intraoperative noise intensity during hip arthroplasty and the postoperative risk of kinesiophobia: a prospective cohort study.Frontiers in surgery · 2026
- Occupational hazards in hip and knee adult reconstruction surgery : a systematic review of physical and psychological stressors.Bone & joint open · 2026
- Operating room noise levels in anaesthesia a systematic review and meta-analysis.British journal of anaesthesia · 2026
- Evaluation of bone-conducted sound during ear surgery: an in vivo pilot study.Biomedical engineering online · 2026
- EP8.12 A descriptive review of 11465 cases recorded in the UK Non-Arthroplasty Hip Registry (NAHR) and analysis of temporal trends in patient demographics, PROMs and surgical proceduresJournal of Hip Preservation Surgery · 2026