FP7.1 A pilot study of AI-driven 3D reconstruction from a single radiograph for acetabular version assessment
Mr Roel Huysentruyt, ir Ide Van den Borre, Prof Emmanuel Audenaert
Key points
From the paper's conclusion- This pilot study shows that AI-driven 3D reconstruction from a single AP radiograph can estimate acetabular version with clinically promising accuracy.
Abstract
ICLB07 - The Digital Surgeon: Practical Tools and Navigation Basics for Your Everyday Practice, Session Room 12 (BMCC Level 3), October 8, 2026, 14:00 - 16:00 Acetabular version (AV) is a clinically relevant parameter describing femoral head coverage in the axial plane, which cannot be directly observed on standard anteroposterior (AP) radiographs. Accurate estimation typically requires CT imaging. This study investigates whether AV can be reliably derived from a single AP hip radiograph using AI-based 3D reconstruction. A retrospective dataset of 94 asymptomatic subjects was used, including 75 training cases and 19 evaluation cases with corresponding CT ground truth. CT scans had an isotropic resolution of 1 mm. The cohort consisted of 54 males and 42 females with a mean age of 67 years. For each subject, a single AP radiograph of the hip joint centered on the femoral head was used as input. This was obtained for both the left and right hip. A deep implicit neural network framework was trained to reconstruct a patient-specific 3D volumetric representation from the 2D radiograph, producing both a CT-like volume and corresponding 3D bone models. Acetabular version was computed at on the reconstructed bone models and compared to measurements derived from the original CT-based bone models. AV was measured consistently at the level of the femoral head center in both modalities. The proposed method demonstrated strong agreement between predicted bone models and the CT measurements. The mean absolute error for acetabular version was 2.05° with a standard deviation of 1.33°. The 95% confidence interval ranged from 1.58° to 2.52°. Two outliers were observed with deviations up to 9°, likely related to imperfect reconstruction. This pilot study shows that AI-driven 3D reconstruction from a single AP radiograph can estimate acetabular version with clinically promising accuracy. The results suggest that 3D anatomical inference from limited 2D imaging may enable extraction of otherwise inaccessible biomechanical parameters. Future work will focus on expanding this to other parameters, improving robustness the address the outlier cases, and validating performance on larger and more pathological cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- TP4.7 Identifying Three-Dimensional Acetabular Morphologic Characteristics Associated with the Presence of Radiographic Indicators of Acetabular Retroversion: A Statistical Shape Modeling AnalysisJournal of Hip Preservation Surgery · 2026
- Pelvis-Based Three-Dimensional Hip Morphology in Japanese Women: Reference Distributions and Spatial Relationships of Femoral Head Position, Acetabular Orientation, and Coverage.Cureus · 2026
- CT-based navigation for acetabular cup placement in supine and lateral positions: a simulated surgery study using patient-specific 3D-printed pelvic models.Frontiers in surgery · 2026
- Robotic-referenced automated measurement of acetabular cup orientation on postoperative CT: development and internal validation.Journal of robotic surgery · 2026
- TP4.8 Automated 3D Hip Landmark Detection Using Supine and Weight-Bearing CT Imaging: A Validation StudyJournal of Hip Preservation Surgery · 2026
- Improving Recognition Performance and Reader Efficiency for Femoral-Neck Fracture Detection on Pelvic or Hip Radiographs Using Artificial Intelligence.Radiology · 2026