Journal of Hip Preservation Surgery

TP4.8 Automated 3D Hip Landmark Detection Using Supine and Weight-Bearing CT Imaging: A Validation Study

MSc Ide Van den Borre, MD Jasper Lambrechts, MD Aline Van Oevelen, BSc Emile Versluys, MSc Robin Vanhauwe, MD, PhD Emmanuel Audenaert

Key points

From the paper's conclusion
  • These findings indicate observer-level performance within the studied cohort and imaging conditions.

Abstract

Background Accurate identification of pelvic and proximal femoral landmarks is essential for CT-based hip assessment, diagnosis, and preoperative planning. However, manual three-dimensional landmarking is time-consuming and subject to observer variability. Automated landmark detection may improve efficiency, standardisation, and reproducibility. Hypothesis An artificial intelligence–based workflow combining automated segmentation with statistical shape model–based landmark transfer can identify clinically relevant hip landmarks on CT with performance comparable to manual interobserver variability. Study design Retrospective validation study. Methods The automated segmentation model used in this workflow was previously developed and trained on 722 CT scans. For the present validation study, 30 CT scans were included: 20 conventional angio-CT scans and 10 weight-bearing CT scans. The pelvis, femur, and sacrum were automatically segmented using this deep learning model. A statistical shape model–based non-rigid fitting procedure was then used to transfer predefined anatomical landmarks to each subject-specific three-dimensional bone model. All models were expressed in a standardised anterior pelvic plane coordinate system. Three observers independently annotated the landmarks on the segmented bone models. Automated landmark locations were compared with manual annotations using three-dimensional Euclidean distance error, and interobserver variability was calculated using pairwise Euclidean distances between observers. Results Automated landmark detection showed close agreement with manual annotations across the evaluated landmarks. In most cases, automated–observer differences were of similar magnitude to the natural interobserver variability. Mean automated errors ranged from 0.00 ± 0.00 mm to 7.61 ± 2.51 mm, while interobserver variability ranged from 0.00 ± 0.00 mm to 7.25 ± 3.40 mm. These findings indicate observer-level performance within the studied cohort and imaging conditions. Conclusion This AI-based workflow demonstrated observer-level performance for automated hip landmark detection. The method appears promising as a standardised and observer-independent tool for CT-based hip morphometric assessment and preoperative planning. Further validation in larger and more heterogeneous populations is needed. Clinical Relevance Automated hip landmark identification may reduce manual workload and improve reproducibility in CT-based planning and three-dimensional hip morphometric analysis. Key Terms deep learning, hip alignment, medical image analysis, statistical shape modelling, computed tomography.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers