Pacing Performance of a Modular Communicative Leadless Pacing-Defibrillator System.
Lluís Mont, Michael S Lloyd, Paul R Roberts, Rahul Doshi, David J Wright, Paul A Friedman, Petr Neuzil, Carina Blomstrom-Lundqvist,
Institut Clínic Cardiovascular, Hospital Clínic, Universitat de Barcelona. Barcelona, Spain. · Emory University Section of Cardiac Electrophysiology, Atlanta, GA, USA.
Key points
From the paper's conclusion- Conclusions The performance of the modular pacing-defibrillator system at one year demonstrated a low complication rate and reliable pacing functionality.
Abstract
BACKGROUND AND AIMS: MODULAR ATP is an ongoing trial assessing the efficacy of a subcutaneous implantable cardioverter defibrillator (S-ICD) in communication with a leadless pacemaker (LP) that can deliver bradycardia pacing and antitachycardia pacing. The objective of this study was to assess safety and pacing performance of the investigational LP. METHODS: The study enrolled patients with an ICD indication and at high risk for monomorphic ventricular tachycardia. Pacemaker dependent patients were excluded. Primary safety endpoint 2 was the percentage of patients free from major LP-related complications at 12 months. The secondary effectiveness endpoint assessed the rate response performance of the LP under workload. Parameters related to the pacing performance were also measured. RESULTS: In 297 patients, the mean age was 59±12 years, the mean left ventricular ejection fraction was 35.3±13.1%, and 17.5% were female. LP implant was attempted in 286 patients and was successful in 100%. The major LP-related complication free rate at 12 months was 97.2% (one-sided 97.5% LCL 94.5%), surpassing the performance goal of 81%. There were no LP-related complications following Implant. For the secondary effectiveness endpoint, the slope of the normalized sensor rate versus the normalized workload was 0.96 (95% LCL 0.91, 95% UCL 1.02), within the performance goal range of 0.65-1.35. At 12 months, 96.8% of patients had a pacing capture threshold ≤ 2V @ 0.4ms pulse width. CONCLUSIONS: The performance of the modular pacing-defibrillator system at one year demonstrated a low complication rate and reliable pacing functionality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Leadless Versus Transvenous Pacing: Propensity-Matched 12-Month Outcomes.Pacing and clinical electrophysiology : PACE · 2026
- One Catheter, Two Chambers: Feasibility and Acute Procedural Outcomes of Dual-Chamber Leadless Pacemaker Implantation with a Single Delivery Catheter.Journal of clinical medicine · 2026
- First short-term European experiences with dual-chamber leadless pacing: Early safety and electrical outcomes compared with transvenous systemsKardiologia Polska · 2026
- A decade of leadless pacemaker implantation: technical performance, safety and device longevityEuropean Heart Journal · 2026
- Lose the Hardware: The Rise of Leadless Modular Cardiac Pacing.Journal of clinical medicine · 2026
- Concomitant Aveir AR and Micra AV2 Hybrid Leadless Implantation During Infected Pacemaker Extraction.Pacing and clinical electrophysiology : PACE · 2026