The evolution of Extravascular Cardioverter Defibrillator implantation: feasibility in a purely electrophysiologic setting.
Mauro Biffi, Hans Römers, Andrea Quaranta, Antonio Nicolò Izzo, Carmine Verde, Alberto Spadotto, Andrea Angeletti, Cristian Martignani,
IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy. · Cardiology Department, St. Antonius Hospital Nieuwegein, Nieuwegein, The Netherlands.
Key points
From the paper's conclusion- EV-ICD implantation can be safely and effectively performed under cardiologist-directed sedation without anesthesiology supervision, achieving a fully electrophysiology-driven workflow. Procedural simplification substantially reduces resource utilization and may facilitate broader adoption of this technology.
Abstract
BACKGROUND: extravascular implantable cardioverter-defibrillator (EV-ICD) is a novel non-transvenous system delivering defibrillation shocks and anti-tachycardia pacing through a substernal lead. Despite proven efficacy, implantation has traditionally required general anesthesia and cardiothoracic surgical backup, limiting widespread adoption. OBJECTIVES: To evaluate feasibility, safety, and workflow efficiency of EV-ICD implantation under cardiologist-directed sedation without anesthesiology support. METHODS: Prospective observational study including 115 consecutive patients undergoing EV-ICD implantation across two European centers. Three procedural settings were explored sequentially: general anesthesia (GA, n=46), analgosedation without anesthesiology supervision (AS, n=28), and regional block with limited sedation (RBS, n=41). The primary endpoint was successful implantation without conversion to respiratory or circulatory support. Secondary endpoints included procedure duration, procedure-related complications, and device performance at follow-up. RESULTS: Overall implantation success was 97% (112/115) in a predominantly young population (50±17 years; 70% male). All procedures performed without anesthesiology supervision were completed without conversion to GA or emergency support, with comparable complication rates across groups. RBS was associated with a 27-minute reduction in procedural duration versus GA (p<0.001) and earlier mobilization (97% ambulating within 3 hours vs. 65% after 6 hours with GA; p<0.001). Over a median follow-up of 20 [10-30] months, appropriate ICD therapy was delivered in 13% of patients with 100% arrhythmia termination. Inappropriate therapy occurred in 8.9%, predominantly during the early learning phase. CONCLUSIONS: EV-ICD implantation can be safely and effectively performed under cardiologist-directed sedation without anesthesiology supervision, achieving a fully electrophysiology-driven workflow. Procedural simplification substantially reduces resource utilization and may facilitate broader adoption of this technology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Extravascular Implantable Cardioverter-Defibrillators in Children: Real World Evidence.Pediatric cardiology · 2026
- A Review of Anesthetic Considerations for Subcutaneous and Extravascular Implantable Cardioverter-Defibrillators.Seminars in cardiothoracic and vascular anesthesia · 2026
- Transient Defibrillation Threshold Elevation Associated With Air in the Generator Pocket After Extravascular ICD ImplantationHeartRhythm Case Reports · 2026
- The extravascular ICD: Evolving paradigms in sudden death preventionHeart Rhythm · 2025
- Videoscopic-guided retrosternal access for extravascular icd implantation: a technique to enhance safety and lead positioningEuropean Heart Journal · 2026