Extravascular Implantable Cardioverter-Defibrillators in Children: Real World Evidence.
Jack C Luxford, Jacqueline Nguyen Khuong, David Manning, Hiroko Asakai, Christian Turner, Julian Ayer, Matthew Liava'a, Claire M Lawley
Heart Centre for Children, The Children's Hospital at Westmead, Sydney, NSW, 2145, Australia. jack.luxford@health.nsw.gov.au. · Heart Centre for Children, The Children's Hospital at Westmead, Sydney, NSW, 2145, Australia.
Key points
From the paper's conclusion- The extravascular implantable cardioverter-defibrillator (EV-ICD) is a novel substernal ICD with limited reports in children and adolescents.
Abstract
The extravascular implantable cardioverter-defibrillator (EV-ICD) is a novel substernal ICD with limited reports in children and adolescents. Single-centre review of EV-ICDs in children <18-years. Clinical, peri-procedural, and electrocardiographic data reviewed, including device performance in routine exercise stress testing. Median follow-up 10.9 (IQR 7.5 - 12.5) months. Between April 2025-April 2026, 15 EV-ICDs were successfully implanted by a single cardiothoracic surgeon: median age 13.8-years, IQR 10.2-16.4; 11 (73%) male; weight 52 kg, IQR 38.2-64.1; BSA 1.6 m2, IQR 1.2-1.8. Smallest child was 4-years, 17.3 kg (BSA 0.7 m2). Indications were primary (n = 10) and secondary (n = 5) prevention. Underlying diagnoses included cardiomyopathy (n = 9), channelopathy (n = 3). One child had a previous sternotomy and another severe chest-wall deformity. Median anaesthetic time was 148 min (IQR 130-161), surgical time 68 min (59-88), fluoroscopy time 2.6 min (2.2-3.8). Median 3 (IQR 2-4) day hospitalisation. Two children experienced early complications. In one child, defibrillator threshold testing terminated ventricular fibrillation (VF) into ventricular tachycardia (VT) requiring CPR and a decision to use external cardioversion. The child fully recovered. One adolescent experienced profound bradycardia and syncope early post anaesthesia. R-wave amplitude at implant (5mV, IQR 4.2 - 6.7), discharge (5, IQR 2.8 - 8.1) and latest follow-up (5.8, IQR 3.2 - 13.7) was stable. Device sensing during routine exercise stress testing has been appropriate. There has been one successful appropriate high voltage therapy and no inappropriate high voltage therapy. This is the largest single-centre series internationally, demonstrating reliable paediatric EV-ICD implantation and short-term device performance. Ongoing paediatric surveillance is necessary.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The evolution of Extravascular Cardioverter Defibrillator implantation: feasibility in a purely electrophysiologic setting.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Impact of anatomical factors and implantation position on defibrillation threshold in extravascular implantable cardioverter-defibrillatorEuropean Heart Journal · 2026
- Transient Defibrillation Threshold Elevation Associated With Air in the Generator Pocket After Extravascular ICD ImplantationHeartRhythm Case Reports · 2026
- A Review of Anesthetic Considerations for Subcutaneous and Extravascular Implantable Cardioverter-Defibrillators.Seminars in cardiothoracic and vascular anesthesia · 2026
- The extravascular ICD: Evolving paradigms in sudden death preventionHeart Rhythm · 2025
- Real-World Experience With the Extravascular Implantable Cardioverter Defibrillator Through 1 Year: The Enlighten Post Approval Registry Study.Circulation · 2026