Videoscopic-guided retrosternal access for extravascular icd implantation: a technique to enhance safety and lead positioning
M Mraiyan, B Doty, M Khan, D Nair
Key points
From the paper's conclusion- Objective We aim to assess the safety and feasibility of a videoscopic-guided system (VSGS) to improve substernal access and lead positioning during EV-ICD implantation.
Abstract
Background The extravascular implantable cardioverter-defibrillator (EV-ICD) offers a less invasive alternative to transvenous systems while maintaining effective defibrillation. Substernal tunneling remains the most challenging step, as limited visualization increases the risk of pleural or pericardial injury and suboptimal lead placement. Objective We aim to assess the safety and feasibility of a videoscopic-guided system (VSGS) to improve substernal access and lead positioning during EV-ICD implantation. Methods Patients underwent EV-ICD implantation using video-assisted substernal access with VSGS. Through a left lateral xiphoid incision, a thoracoscope was advanced to directly visualize the substernum and pericardium. Under combined video and fluoroscopic guidance, a tunneling tool was advanced from the xiphoid along the retrosternal space, ensuring continuous visualization to avoid pleural or pericardial breach. The lead was then passed into the retrosternal space anterior to the right ventricle and connected to the generator in the lateral pocket Procedural metrics, lead parameters, and acute complications were recorded. Results Nine patients (42% male, mean age 57 ± 12 years) successfully underwent EV-ICD implantation using the VSGS approach. Direct substernal visualization and first-pass lead placement anterior to the right ventricle were achieved in all cases. No pericardial or pleural entry, vascular injury, or need for surgical conversion occurred. Mean fluoroscopy time was 8 ± 6 minutes, and total procedure time was 26 ± 8 minutes. Defibrillation thresholds were acceptable with stable electrical parameters, and no acute complications or major device-related events were observed. Conclusion Real-time visualization with VSGS enables precise substernal RV lead placement and enhances safety during EV-ICD implantation. This early experience demonstrates feasibility and safety, though larger studies are needed to confirm broader applicability.Tunneling Device
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transient Defibrillation Threshold Elevation Associated With Air in the Generator Pocket After Extravascular ICD ImplantationHeartRhythm Case Reports · 2026
- The extravascular ICD: Evolving paradigms in sudden death preventionHeart Rhythm · 2025
- Transient Pneumopericardium During Implantation of an Extravascular Implantable Cardioverter-Defibrillator.JACC. Case reports · 2026
- A Review of Anesthetic Considerations for Subcutaneous and Extravascular Implantable Cardioverter-Defibrillators.Seminars in cardiothoracic and vascular anesthesia · 2026
- The evolution of Extravascular Cardioverter Defibrillator implantation: feasibility in a purely electrophysiologic setting.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Endo-Epicardial Ventricular Tachycardia Ablation With Pulsed-Field Energy in an Extravascular ICD RecipientJACC Case Reports · 2026