European Heart Journal

Real-world outcomes of subcutaneous ICD implants: a single-centre experience

J Dixon, E A Zoumi, S F Ali, A Hawley, B Dyer, P Spurrell, M Muggenthaler, H Edwards,

Observational

Key points

From the paper's conclusion
  • When compared with the PRAETORIAN S-ICD arm, in which 83 of 426 patients (19.5 %) received an appropriate shock, there was again no statistically significant difference (p = 0.42; RR 0.82 [95 % CI 0.49–1.38]).3 Conclusion(s) In this single-centre DGH experience, S-ICD implantation produced event rates and follow-up duration comparable to large trial data.

Abstract

Background/Introduction Subcutaneous implantable cardioverter-defibrillators (S-ICDs) avoid intravascular leads and reduce long-term lead-related complications when compared with transvenous systems.1,2 While large multicentre trials support their safety, outcomes from lower-volume, non-tertiary hospitals are less well characterised. Purpose To report real-world clinical outcomes following all S-ICD implantations at a single large district general hospital (DGH) in the United Kingdom and provide centre-level benchmarking against published trial data. Methods We retrospectively reviewed consecutive S-ICD implants performed at our centre between 2017–2025. Patients with no follow-up were excluded. The primary composite endpoint included the first occurrence of a device-related complication or an inappropriate shock. Time-to-event analyses used Kaplan–Meier (KM) methods. Crude proportions were compared with the PRAETORIAN S-ICD arm using Fisher’s exact test.3 A secondary time-to-first appropriate shock analysis was performed. Results There were 81 patients in the study cohort (mean age 50 years; 77% male). Reverse-KM median follow-up was 39.4 months. 16 patients (19.8%) met the primary composite endpoint. Components included 10 inappropriate shocks and device-related complications (1 infection, 1 lead fracture, 3 device extractions for device-related issues and 1 generator repositioning). There were 4 deaths, none attributed to the device. The 36-month KM cumulative incidence of the primary composite endpoint was 20.1 % (95 % CI 8.9–29.9), increasing to 26.0 % (95 % CI 12.3–37.5) at 48 months. The event rate was 6.8 per 100 patient-years (95 % CI 3.9–11.1). Compared with the PRAETORIAN S-ICD cohort (68/426 [16%] patients met the primary endpoint), there was no statistically significant difference in crude event proportions (p = 0.42; RR 1.24 [95 % CI 0.76–2.02]).3 13 patients (16.0 %) received at least one appropriate shock during follow-up. The reverse-KM median follow-up for this analysis was 32.5 months, with a 48-month cumulative incidence of 23.3 % (95 % CI 9.1–35.3) and an event rate of 6.0 per 100 patient-years (95 % CI 3.2–10.3). When compared with the PRAETORIAN S-ICD arm, in which 83 of 426 patients (19.5 %) received an appropriate shock, there was again no statistically significant difference (p = 0.42; RR 0.82 [95 % CI 0.49–1.38]).3 Conclusion(s) In this single-centre DGH experience, S-ICD implantation produced event rates and follow-up duration comparable to large trial data. The 4-year cumulative risk of device-related complication or inappropriate shock is clinically notable and underlines the importance of careful patient selection, procedural planning and structured follow-up pathways in DGH practice. Limitations of our study include the retrospective design and modest sample size; further multi-centre DGH data and pooled analyses would improve precision.KM Primary Composite EndpointKM Appropriate Shock

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers