科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ EP Europace2025-11-10· Medicine

Micra leadless pacemaker revisions: incidence, characteristics, and outcomes from a multicentre French cohort

Peggy Jacon, Mouna Ben Kilani, Arnaud Bisson, Éloi Marijon, Antoine Da Costa, Christelle Haddad, Nathalie Béhar, Olivier Césari, Nicolas Lellouche, Vincent Mansourati, Jean‐Luc Pasquié, Romain Eschalier, Pierre Ollitrault, Hugues Blangy, Pierre Bordachar, L Morel, Pierre Mondoly, Xavier Waintraub, Antoine Andorin, Frédéric Anselme, Pierre Frey, Rodrigue Garcia, Benoît Guy-Moyat, Guillaume Serzian, Morin Christelle, Alexis Mechulan, Baptiste Maille, Nathan Vaxelaire, Rémi Benali, Adrien Carabelli, Sandrine Venier, Pascal Defaye

原始摘要(英文原文)· Original abstract
AIMS: Leadless pacemakers (LLPs) offer a valuable option for selected patients requiring ventricular pacing. However, data on revision procedures-defined as any intervention on an implanted LLP to correct dysfunction or upgrade the system, with or without removal-remain scarce. This study aimed to evaluate the real-world incidence, characteristics, and outcomes of LLP revisions, with particular emphasis on the feasibility and safety of removal. METHODS AND RESULTS: This multicentre retrospective study involved 46 French centres performing LLP implantations between 2015 and 2023. Among 8994 Micra LLPs implanted, 100 revision procedures (1.1%) were performed in 100 patients, including 73 Micra VR and 27 Micra AV devices, at a median follow-up of 229 (68.5-629.8) days. Seventy revisions were managed without device removal, while 30 involved removal. Revision indications included device upgrade (55%), high pacing threshold (33%), battery depletion (3%), ventricular arrhythmias (3%), and miscellaneous causes (6%). No significant differences were observed in pacing indications, implantation characteristics, or initial device indication between the two groups. Revisions occurred significantly earlier in the removal group than in the group without removal [median 81.5 (8-211.5) days, vs. 334 (130.25-882.5) days, P < 0.001], with 80% occurring within 1 year. Device removal was successful in 97% of cases (one failure at 157 days of follow-up), with no major complications reported. CONCLUSION: LLP revisions are infrequent and predominantly managed without device removal. However, given the high procedural success rate and the low complication rate, device removal appears to be underutilized and should be considered more frequently on a case-by-case basis.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Micra leadless pacemaker revisions: incidence, characteristics, and outcomes from a multicentre French cohort — 科研速览 Science Skim