Prosthesis-Patient Mismatch and Patient-Centered Outcomes After TAVR.
Ottavia Cozzi, Daijiro Tomii, Jonas Lanz, Holger Thiele, Dik Heg, Michael Joner, Helge Möllmann, Axel Linke,
Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland; Cardio Center, IRCCS Humanitas Research Hospital, Rozzano-Milan, Italy. · Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.
Key points
From the paper's conclusion- Among survivors, severe PPM was associated with a lower likelihood of good health status at 3 years. This association was attenuated after accounting for 30-day residual mitral regurgitation, suggesting a possible contributory role. Given the post hoc design, the findings are hypothesis-generating.
Abstract
BACKGROUND: Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement has been widely studied for its association with clinical outcomes, but its effect on patient-reported health status remains less defined. OBJECTIVES: This study sought to evaluate the association between PPM severity and health status through 3-year follow-up after transcatheter aortic valve replacement. METHODS: This post hoc analysis of the SCOPE I (Safety and Efficacy of the ACURATE Neo/TF Compared to the SAPIEN 3 Bioprosthesis) randomized trial categorized patients according to PPM severity using Valve Academic Research Consortium-3 criteria. Endpoints included survival and patient-reported health status, with an integrated outcome defined as being alive with good health status (Kansas City Cardiomyopathy Questionnaire Overall Summary score ≥75 without a decline of >10 points from baseline). RESULTS: Among 662 patients, moderate and severe PPM occurred in 184 (27.8%) and 69 (10.4%), respectively. All-cause mortality at 1 and 3 years was 7.0% and 20.5%, with no differences across PPM categories. Kansas City Cardiomyopathy Questionnaire Overall Summary score was similar through 1 year but lower at 3 years in patients with severe vs no PPM (median 71.1 vs 83.9; P = 0.027). Fewer patients with severe PPM were alive with good health status at 3 years (30.6% vs 49.4%; P = 0.021). In multivariable analysis, severe PPM was associated with a lower likelihood of the integrated outcome (OR: 0.51; 95% CI: 0.27-0.96; P = 0.036), but this association was no longer statistically significant after adjustment for 30-day mitral regurgitation (OR: 0.59; 95% CI: 0.30-1.15; P = 0.121). CONCLUSIONS: Among survivors, severe PPM was associated with a lower likelihood of good health status at 3 years. This association was attenuated after accounting for 30-day residual mitral regurgitation, suggesting a possible contributory role. Given the post hoc design, the findings are hypothesis-generating.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mid-term impact of prosthesis-patient mismatch after transcatheter aortic valve implantation using a self-expanding or balloon-expandable transcatheter heart valveEuropean Heart Journal · 2026
- Long-term impact of prosthesis-patient mismatch after transcatheter aortic valve replacement.Cardiovascular intervention and therapeutics · 2026
- Prosthesis–Patient Mismatch Following Aortic Valve Replacement—A Comprehensive ReviewJournal of Clinical Medicine · 2025
- Sex-Specific Differences in Patient-Centered Outcomes After Transcatheter Aortic Valve Replacement.JACC. Advances · 2026
- Incidence, Predictors, and Outcomes of Patient-Prosthesis Mismatch After Surgical Aortic Valve Replacement.Heart, lung & circulation · 2026
- Understanding prosthesis patient mismatch in aortic valve replacement: from pitfalls to clinical impact.Cardiovascular intervention and therapeutics · 2026