Clinical yield of discharge transthoracic echocardiography in transcatheter aortic valve implantation patients from a contemporary cohort
O Ward, A Alhakak, E L Brogaard, T S Soerensen, L M Soerensen, J E Strange, A A Raja, O De Backer,
Key points
From the paper's conclusion- These findings suggest limited overall clinical yield of routine discharge echocardiography after TAVI.
Abstract
Background Transcatheter aortic valve implantation (TAVI) procedural volumes are increasing, and advances in technology have contributed to lower complication rates and shorter hospitalizations. After TAVI, routine transthoracic echocardiography (TTE) is still performed before discharge and repeated at 3-month follow-up in Denmark. However, the clinical yield of discharge TTE has not been examined systematically. Purpose To examine the clinical yield of post-procedure, pre-discharge echocardiography in TAVI patients from a contemporary cohort. Methods We included all patients who underwent TAVI in Eastern Denmark in 2023–2024. The population was stratified by simple (tricuspid valve, transfemoral access) vs complex procedures (bicuspid valve, valve-in-valve, or alternative access). The discharge TTE was defined as clinically relevant if it led to one of the following: 1) additional early follow-up TTE; 2) new transoesophageal echocardiography for further valve assessment; 3) reintervention; 4) or if it revealed post procedural fall in LVEF to <40%. Results A total of 894 patients were included (62.1% male; median age 80.0 years [IQR 76.5–83.7]), of whom 723 (80.9%) underwent a simple procedure and 171 (19.1%) a complex procedure. Patients who underwent a simple procedure were older than those who underwent a complex procedure (80.6 vs 78.0 years; P<0.001). Overall, comorbidities were similar between groups. Clinically relevant findings were detected in 25 (2.8%) patients: 16 (2.2%) in the simple group vs 9 (5.3%) in the complex group (P=0.03). Among these 25 patients, TTE led to additional follow-up TTE in 12 (48%), transoesophageal echocardiography for further valve assessment in 6 (24%), referral to a heart failure clinic in 6 (24%) (due to LVEF drop to <40%), and reintervention in one (4%) patient (Figure). Conclusion In a contemporary TAVI cohort, approximately 3% of patients had a clinically relevant TTE finding that prompted further investigation. Among these, 6 patients were referred to a heart failure clinic and one patient underwent reintervention. These findings suggest limited overall clinical yield of routine discharge echocardiography after TAVI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Longitudinal trends and outcomes in transcatheter aortic valve implantation: a report from the Swiss TAVI registryEuropean Heart Journal · 2026
- Echocardiographic predictors of mortality in infective endocarditis after transcatheter aortic valve implantationEuropean Heart Journal · 2026
- Multimodal CT-echocardiographic score for preprocedural prediction of permanent pacemaker implantation after transcatheter aortic valve replacementEuropean Heart Journal · 2026
- Transcatheter aortic valve implantation and need for post-discharge pacemaker implantation in the modern era of fast dischargeEuropean Heart Journal · 2026
- Transmitral mean pressure gradient after transcatheter aortic valve replacement and late mortalityEuropean Heart Journal · 2026
- Post-implant CT volumetry shows frequent divergence between segmented and nominal factory valve volume after TAVIEuropean Heart Journal · 2026