From the paper's conclusion- Development of clinical heart failure during admission further increased mortality risk (HR 3.95, p<0.001).
Abstract
Introduction The use of transcatheter aortic valve implantation (TAVI) is already the dominant treatment for severe aortic stenosis and is expected to increase following recent international guideline updates. By lowering the age threshold for TAVI, patients who previously would have undergone surgical replacement will instead live longer with a TAVI valve, thereby increasing their cumulative lifetime risk of TAVI-associated infective endocarditis (TAVI-IE), a serious complication. Echocardiography is essential for the diagnosis and follow-up of TAVI-IE. Purpose To assess associations between echocardiographic measurements of left ventricular (LV) systolic function, LV geometry, and mortality in patients with TAVI-IE. Methods We included 71 consecutive patients with TAVI-IE who had undergone TAVI at the same tertiary centre between 2012 and 2023. Transthoracic echocardiography was performed at baseline before TAVI, at routine postoperative follow-up, and shortly after admission for TAVI-IE. The primary outcome was all-cause mortality. Cox-regression models were used to evaluate predictors of mortality. Results Mean LV ejection fraction (LVEF) was 56±11% at baseline, 57±9% at first postoperative follow-up, and 53±12% at admission for TAVI-IE (p=0.008 for baseline versus TAVI-IE). From baseline to admission for TAVI-IE, LV stroke volume declined from 79±23 mL to 66±25 mL (p=0.005). LV end-diastolic diameter did not change from baseline to TAVI-IE. There were 42 (59%) deaths during a mean follow-up of 2.7±2.3 years of follow-up after admission for TAVI-IE. Reduced LVEF (<50%) at baseline (HR 2.42, p=0.011), postoperative follow-up (HR 2.36, p=0.019), and at TAVI-IE diagnosis (HR 2.36, p=0.008) was associated with higher mortality. At admission for TAVI-IE, low LV stroke volume (<60 mL, HR 3.04, p=0.006) and low indexed LV stroke volume (<25 mL/m2, HR 2.30, p=0.043) were also associated with increased mortality. Development of clinical heart failure during admission further increased mortality risk (HR 3.95, p<0.001). LV mass, LV dilatation, paravalvular leakage and valvular vegetations were not associated with mortality. Conclusion In patients with TAVI-IE, reduced LVEF and LV stroke volume during hospitalization for TAVI-IE are strongly associated with mortality, underscoring the prognostic importance of routine assessment of LV systolic function in this high-risk population.Visual abstract
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Global myocardial performance and long-term mortality after TAVI: prognostic value of the TEI indexEuropean Heart Journal · 2026
- Prognostic Value of Tissue Doppler Late Diastolic Velocity (TDI-a') in Patients with Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation.The American journal of cardiology · 2026
- Prognostic impact of cardiovascular magnetic resonance-derived left atrioventricular coupling index in patients with severe aortic stenosis undergoing transcatheter aortic valve replacementEuropean Heart Journal · 2026
- Serial Changes in Left Ventricular Ejection Fraction After Transcatheter Aortic Valve Implantation: Associations With Ischemic Heart Disease and Left Ventricular End-Diastolic Diameter.Echocardiography (Mount Kisco, N.Y.) · 2026
- Infective endocarditis following transcatheter valvular interventions (transcatheter aortic valve implantation and transcatheter edge-to-edge repair).Kardiologia polska · 2026
- Risk of endocarditis after transcatheter aortic valve implantation (TAVI) in patients under hemodialysisEuropean Heart Journal · 2026