Association of Positive Airway Pressure With Non-Smoke Spontaneous Individual Contrast During Simulated Valsalva Loading
Yumi Yamamoto, Yasuhide Mochizuki, Ken Oshima, Mamiko Yamada, Ayaka Oda, Sakiko Gohbara, Saaya Ichikawa-Ogura, Rumi Hachiya,
Key points
From the paper's conclusion- Conclusions NSSIC occurrence increased with higher positive airway pressure during simulated Valsalva loading.
Abstract
Background Microbubble testing during the Valsalva manoeuvre (VM) is essential for diagnosing patent foramen ovale (PFO), but non-smoke spontaneous individual contrast (NSSIC) may mimic right-to-left shunt (RLS). We investigated the association between graded positive airway pressure during simulated Valsalva loading and NSSIC. Methods This single-centre retrospective observational study included 35 consecutive patients undergoing transcatheter PFO closure between December 2024 and November 2025. Under general anaesthesia, positive airway pressures of 10, 20, and 30 cmH2O were applied for 10 seconds and abruptly released without contrast injection. Repeated measurements were analysed using mixed-effects logistic regression for left atrial (LA) NSSIC and generalized estimating equations for right atrial (RA) NSSIC. Results RA NSSIC occurred in 26/33 (78.8%), 34/35 (97.1%), and 34/35 (97.1%) at 10, 20, and 30 cmH2O. Compared with 10 cmH2O, the odds were higher at both 20 and 30 cmH2O (OR 8.985, 95% CI 1.332–60.62; p = 0.024 for both), with identical RA NSSIC status at 20 and 30 cmH2O. LA NSSIC increased from 3/33 (9.1%) to 11/35 (31.4%) and 23/35 (65.7%); each 10-cmH2O increase was associated with higher odds of LA NSSIC (OR 5.815, 95% CI 2.793–12.11; p < 0.001). Conclusions NSSIC occurrence increased with higher positive airway pressure during simulated Valsalva loading. Recognition of this phenomenon is important to avoid false-positive interpretation of RLS during microbubble testing for PFO.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pre-procedural shunt characteristics and residual shunting at 6 months after percutaneous PFO closureEuropean Heart Journal · 2026
- Noninvasive Cardiac Arrest Recognition Using Wearable Sensors in a Porcine Model of Ventricular Fibrillation.bioRxiv : the preprint server for biology · 2026
- Automated Versus Manual Occlusion Pressure at 100 ms With Hamilton C6 Using the Software Version 1.2.3: From Bedside to the Bench and Back to Bedside.Critical care explorations · 2026
- Impact of pulsed-field ablation of the right superior pulmonary vein on conduction block in the superior vena cavaEuropean Heart Journal · 2026
- Platypnea-Orthodeoxia Syndrome Due to a Functional Patent Foramen Ovale: Aortic Dilatation and Possible Contribution of Obstructive Sleep Apnea.Open respiratory archives · 2026
- Femoral Artery Compression Ultrasound as an Adjunct to Clinical Return of Spontaneous Circulation Assessment During Cardiopulmonary ResuscitationJournal of Ultrasound in Medicine · 2026