Femoral Artery Compression Ultrasound as an Adjunct to Clinical Return of Spontaneous Circulation Assessment During Cardiopulmonary Resuscitation
Lalegül Coşkun, Ejder Saylav Bora, Efe Kanter, Semih Musa Coşkun, Mehmet Göktuğ Efgan
Key points
From the paper's conclusion- Conclusions POCUS‐FAC may be a rapid and feasible vascular ultrasound adjunct to clinical ROSC assessment during CPR.
Abstract
Objectives Cardiopulmonary resuscitation requires rapid assessment of return of spontaneous circulation (ROSC), but manual pulse palpation is subjective and may be unreliable in low‐flow states. This study aimed to evaluate the feasibility and diagnostic performance of femoral artery compression ultrasound (POCUS‐FAC) as an adjunct to clinical ROSC assessment during CPR. Methods This single‐center prospective observational feasibility study compared POCUS‐FAC findings with clinician‐adjudicated ROSC decisions in adult emergency department patients with non‐traumatic cardiac arrest. POCUS‐FAC included transverse femoral artery visualization, standardized compressibility assessment, and visible pulsation recording. Failure of the femoral artery to compress was defined as a positive compression finding. The resuscitation team leader, blinded to POCUS‐FAC findings, made the ROSC decision using manual pulse palpation, monitor rhythm, clinical signs of circulation, respiratory effort, and measurable blood pressure when available. Results Of 57 evaluated patients, 52 were included. Clinician‐adjudicated ROSC occurred in 24 patients, whereas 28 patients did not achieve ROSC. A total of 2196 POCUS‐FAC and 549 manual palpation assessments were recorded. POCUS‐FAC assessment time was shorter than manual palpation time (2.54 s versus 5.81 seconds; p < .001). Using clinician‐adjudicated ROSC as the reference, POCUS‐FAC compression positivity had 95.8% sensitivity and 89.3% specificity. Visible femoral artery pulsation occurred only in patients with clinician‐adjudicated ROSC in this cohort. In 23 patients, compression positivity preceded manual pulse recognition; however, this finding should be interpreted in light of the more frequent POCUS‐FAC sampling schedule. Conclusions POCUS‐FAC may be a rapid and feasible vascular ultrasound adjunct to clinical ROSC assessment during CPR. Before independent diagnostic use, it should be validated against objective hemodynamic measures such as invasive arterial pressure or Doppler‐derived flow.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating hands-free carotid Doppler ultrasound for real-time return of spontaneous circulation detection in in-hospital cardiac arrest: a multicenter randomized controlled studyResuscitation · 2026
- Serial Ultrasound-Guided Carotid Artery Compression During Chest Compressions for Assessing Circulatory Status: A Prospective Pilot Diagnostic Study.Diagnostics (Basel, Switzerland) · 2026
- POCUS in pediatric arrest (Res-US pulse check): development and evaluation of a simulation-based curriculumResuscitation Plus · 2026
- Spectral Characteristics and Parameters of Pulse Oximetry Waveforms for Assessing Resuscitation Status.Resuscitation · 2026
- Timing of termination of non-traumatic cardiopulmonary resuscitation in out-of-of hospital setting based on myocardial movements on cardiac ultrasound - analysis from a real-world case report databaseEuropean Heart Journal · 2026
- Front-of-neck point-of-care ultrasound versus capnography for detection of tracheal tube position during cardiopulmonary resuscitation: a randomized simulation-based trialInternational Journal of Emergency Medicine · 2026