B-374 Immunoassay for the Detection of Xylazine in Urine on Beckman Coulter AU480 Analyzer

Ali Pilehvar, Thet Wai, Aaron Vollrath, Bernice Lin, Marie Lin

Key points

From the paper's conclusion
  • We introduce the LZI Xylazine enzyme immunoassay for the qualitative and semi-quantitative detection of xylazine in human urine at 10 ng/mL cutoff.

Abstract

Background Xylazine, an alpha-2 adrenergic receptor agonist approved for veterinary use, is primarily employed as a sedative and analgesic for large animals. Recently, it became a prevalent adulterant in illicit drug supplies across North America and increasingly in other areas. Often found in combination with illicitly manufactured fentanyl, it presents a public health emergency due to elevated overdose risks and respiratory depression. We introduce the LZI Xylazine enzyme immunoassay for the qualitative and semi-quantitative detection of xylazine in human urine at 10 ng/mL cutoff. The assay operates on the principle of competition between xylazine in the sample and xylazine-labeled glucose-6-phosphate dehydrogenase (G6PDH) for a fixed amount of antibody in the reagent. Methods A series of experiments were carried out to validate the performance of the assay on the Beckman Coulter AU480 analyzer including precision, cross-reactivity, limit of detection, linearity, accuracy, and stability studies. Studies were completed in both qualitative (one-point calibration against the 10 ng/mL cutoff calibrator) and semi-quantitative (five-point calibration) modes. To evaluate the assay precision, a modified version of the CLS EP5 protocol was implemented where xylazine was spiked into pooled negative human urine at concentrations of ±25%, ±50%, ±75%, and ±100% of the 10 ng/mL cutoff concentration and tested over 22 non-consecutive days. Within-run and total accuracy were determined by calculating the standard deviation (SD) and percent coefficient of variation (% CV). Cross-reactivity of xylazine, its three main metabolites 4-hydroxy xylazine, 3-hydroxy xylazine and 4-hydroxy xylazine glucuronide along with a comprehensive panel of opioids, alpha-2 agonists and antagonists, and other structurally unrelated compounds were assessed. In total, 30 opioids, 17 alpha-2 agonists and antagonists, and 104 structurally un-related substances were tested. A method comparison study was also performed to assess the assays’ reliability against established methods (LC/MS). To this end, 150 LC/MS-verified samples (a combination of un-altered clinical samples and spiked samples in pooled negative human urine) were tested. Results The assay demonstrated robust precision on the Beckman Coulter AU480 analyzer. Within-run precision of concentrations above the assay's low calibrator yielded SD values from 0.3 mAU to 3.6 mAU, with % CV ranging from 1.8% to 6%, while total precision SD values varied from 0.4 mAU to 5.5 mAU, with % CV between 2.6% to 9.3%. Cross-reactivity against the three major xylazine metabolites, 4-hydroxy xylazine, 3-hydroxy xylazine, and 4-hydroxy xylazine glucuronide was 142.86%, 31.25%, and 52.63%, respectively, and no significant interference was noted from other tested compounds. Method comparison results showed 100% positive agreement between both methods and negative agreements of 89% and 92% for qualitative and semi-quantitative modes, respectively. Discrepant samples were identified only near the cutoff range (±50% cutoff concentration). Conclusion The LZI Xylazine Enzyme Immunoassay yields accurate and reliable results on the Beckman Coulter AU480 clinical analyzer. The assay exhibits high sensitivity in detecting xylazine with minimal interference from structurally related and unrelated compounds.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

B-374 Immunoassay for the Detection of Xylazine in Urine on Beckman Coulter AU480 Analyzer — Science Skim