B-354 Touch-Activated Phlebotomy (TAP) versus Venipuncture for the HepQuant DuO Test

Jordan Planck, Touraj Shokati, Keith Hoffman, Koren Newman, Joanne Imperial

Key points

From the paper's conclusion
  • Conclusion Capillary blood collected using the TAP® device provides analytically and clinically equivalent results to venipuncture for the HepQuant DuO® test.

Abstract

Background Chronic liver disease represents a significant and increasing global health burden, accounting for approximately 4% of deaths worldwide. The HepQuant DuO® test is a laboratory-developed test that quantitatively assesses hepatic function using serum obtained via venipuncture to generate a Disease Severity Index (DSI). Despite its widespread use, venipuncture presents challenges related to patient comfort, accessibility, and logistics. The Touch-Activated Phlebotomy (TAP®) device is a minimally invasive, microneedle-based blood collection system designed to collect capillary blood without traditional venous needle insertion. This study evaluated the analytical and clinical equivalency of TAP®-collected samples compared with venipuncture for the HepQuant DuO® test and assessed sample stability under ambient storage conditions. Methods A controlled, crossover study was conducted in ten subjects comparing blood collection by standard venipuncture and the TAP® device. Following oral administration of d4-cholate, blood samples were collected at 20 and 60 minutes post-dose in accordance with HepQuant DuO® testing protocols. Samples were allowed to clot for 30 minutes and centrifuged at 4°C and 3000×g for 20 minutes prior to analysis. Serum d4-cholate concentrations were quantified using liquid chromatography–tandem mass spectrometry (LC-MS/MS) on an Agilent 1260 Infinity II LC coupled to a Sciex Triple Quad 4500 mass spectrometer. DSI values were calculated and compared between collection methods. Pharmacokinetic parameters, including portal hepatic filtration rate (HFRp) and portal-systemic shunting fraction (SHUNT%), were also evaluated to assess clinical equivalency. For stability assessment, whole blood collected by venipuncture was aliquoted into gel microtainers and stored at room temperature. Samples were analysed on days 0, 1, 3, and 7 following centrifugation under the same conditions, and d4-cholate concentrations and DSI values were compared across storage durations. Results DSI values obtained from TAP® and venipuncture samples demonstrated no clinically meaningful differences, with all paired samples remaining within the predefined clinical equivalency range of ±2. Observed DSI differences ranged from 0.09 to 0.83 across subjects whose baseline DSI values ranged from 10 to 18. Pharmacokinetic parameter analysis showed no clinically meaningful differences between collection methods, with portal hepatic filtration rate (HFRp) values ranging from 10.1 mL/min/kg to 23.9 mL/min/kg and SHUNT% values ranging from 20.2% to 45.2%. In addition, d4-cholate concentrations remained stable for at least seven days under ambient storage conditions in both whole blood and serum. Mean concentration differences were =0.065 µM for whole blood and =0.29 µM for serum across both draw time points. DSI values derived from stability samples remained within ±2 throughout the storage period, with coefficients of variation below 5%. Conclusion Capillary blood collected using the TAP® device provides analytically and clinically equivalent results to venipuncture for the HepQuant DuO® test. The demonstrated stability of d4-cholate in microtainer samples and consistent DSI performance support the use of capillary blood for the determination of d4-cholate concentrations and calculation of parameters from the HepQuant DuO test.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers