B-349 Improving identification of monoclonal IgM associated light chains by MASS-FIX
James Larkin, Mark Martinez, Mindy Kohlhagen, David Murray, Maria Alice Willrich
Key points
From the paper's conclusion- Conclusion The use of the alternative QMPSS-DTT method shows potential to improve the capabilities of the QMPSS assay to identifying IgM monoclonal proteins with glycosylated light chains and would effectively remove the need for IFE in 70% of cases, improving test turnaround time.
Abstract
Background Quantitative M-protein Study, Serum (QMPSS), a laboratory developed test, is used to identify and quantify monoclonal immunoglobulins by MALDI-TOF MS MASS-FIX. Monoclonal IgM proteins with glycosylated light chains (LC) are rare (5% of total M-proteins identified). In a given month approximately 3 cases of the 71 reported IgM monoclonal proteins with glycosylated light chains present with indeterminate kappa or lambda LC. The structure of the intact IgM monoclonal protein may restrict access to the Ig-LC constant region resulting in inefficient isolation. The laboratory uses immunofixation electrophoresis (IFE, Sebia) to confirm the Ig-LC isotype in this scenario. This study evaluates a reduction step prior to LC isolation to enhance the detection of the IgM isotype. Methods For QMPSS analysis, serum is added to five immunoaffinity matrices that target IgG, IgA, IgM, Ig-K, and Ig-L (CaptureSelect). After a binding phase, the serum/bead mixtures are washed to remove unbound protein. Finally, Igs are eluted, and the disulfide bonds are reduced, resulting in purified Ig-components. This step is followed by MALDI-TOF MS (Bruker) analysis. M-protein isotypes are determined by pairing each monoclonal protein’s unique LC mass detected in both heavy chain and LC Ig isolates. Twenty de-identified, residual waste serum samples with IgM-M-proteins without clear LC isotype were collected over several months. The proof-of-concept method modification studied to decrease reliance on IFE included use of 2.5 mcL of 0.5M dithiothreitol (DTT) added to kappa and lambda affinity matrix beads prior to sample addition followed by the QMPSS pre-analytical processing. Results For the 20 IgM glycosylated M-proteins, M-spike concentrations ranged from 0.026 to 0.506 g/dL. Using QMPSS and IFE lab routine protocol, the IgM samples were reported as glyco MK (n=17), biclonal MK+ML (n=1), and 2 samples were reported as negative. 16 of the 20 samples used in the study had IgM kappa monoclonal proteins that were identifiable on IFE. 13 of these IgM kappa monoclonal proteins were also identifiable by QMPSS-DTT. Additionally, 1 IgM kappa monoclonal protein was identifiable on QMPSS-DTT but was reported as equivocal on IFE. Of the 6 samples that the DTT method could not resolve, IFE was positive for 3. As shown by the 3 samples in which the light chain was identified only by IFE, the need for IFE as a confirmatory assay is not fully eliminated. The 3 false negative samples had M-quant values of 0.036g/dL, 0.043g/dL, and 0.117g/dL. More extensive testing would be required to determine the cause and prevalence of the observed discrepancy between IFE and QMPSS-DTT. Conclusion The use of the alternative QMPSS-DTT method shows potential to improve the capabilities of the QMPSS assay to identifying IgM monoclonal proteins with glycosylated light chains and would effectively remove the need for IFE in 70% of cases, improving test turnaround time. Further experimentation and optimization could decrease the number of discrepancies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated peak detection, isotyping and quantitation of M-proteins by MALDI-TOF MS for replacement of immunofixation and serum protein electrophoresisJournal of Immunological Methods · 2026
- Performance evaluation of an automated mass spectrometry system for the measurement and isotyping of monoclonal immunoglobulinsClinica Chimica Acta · 2026
- B-064 Bridging Quantitative MALDI-TOF Mass Spectrometry to IMWG Complete Response: Deriving a Serum Cut-off Equivalent to Negative ImmunofixationClinical Chemistry · 2026
- B-196 Comprehensive clinical validation of the Immunoglobulin Isotypes (GAM) assay for the EXENT® Analyzer assay in monoclonal gammopathiesClinical Chemistry · 2026
- Mass spectrometry-based screening for monoclonal gammopathy in individuals undergoing routine physical examinations: Analyses of consecutive 15,068 cases in China.Clinica chimica acta; international journal of clinical chemistry · 2026
- One clone, one mass: The rise of mass spectrometry in the diagnosis and monitoring of monoclonal gammopathies.Clinica chimica acta; international journal of clinical chemistry · 2026